Cisco 600W Quick Start Manual page 9

Cisco systems redundant power system quick start guide
Table of Contents

Advertisement

• Fully redundant—Figure 7. The power source is fully redundant because there are two AC input modules and two DC
output power modules connected to each external device. If any power module fails, there is a full backup.
Note
This configuration is not supported for switches and hubs.
• Redundant with reboot—Figure 8. In normal operation, the hub or switch is powered directly by its AC power connection.
If the internal power system of the hub or switch fails, the device powers down for about 30 seconds until the Cisco RPS
begins supplying power.
Note
Redundancy with reboot works for the following devices only: FastHub 400 series hubs, Catalyst 1900 series and
Catalyst 2820 switches, and Catalyst 2900 series and Catalyst 3500 series XL switches.
• Mixed quasi-redundant and fully redundant—Figure 9. Three external devices can be powered, with two in
quasi-redundant mode and one in fully redundant mode.
Figure 6
Quasi-Redundant Configuration
DC
Cisco RPS
DC output
External devices
Figure 7
Fully Redundant Configuration
DC
Cisco RPS
DC output
AC
DC
DC
150W or less
AC
DC
DC
AC input
AC
DC
AC input
AC
DC
9