Electrical Connection; Making The Electrical Connection; Flue Connection; Completion - Baxi Bermuda Inset 2 Boiler 50/4 E Manual

Table of Contents

Advertisement

Fig. 20
3 Pin Electrical Plug
Fig. 22
Mains Inlet Cable Clamp
Inlet Plug
Mains Inlet Cable
Boiler Base
Fig. 24
Supplied By www.heating spares.co Tel. 0161 620 6677
4 Pin Electrical Plug
Fig. 23
SL L
N
Fire Cable Clamp
Mains Inlet Cable
Cutouts
Fig. 23a
Flue Outlet Socket
6.0 Installation
6.11
1. The appliance requires an electrical supply
from the heating controls system.
2. A permanent live supply is required.
WARNING: The appliance must be earthed.
The input cable for the appliance should be
0.75mm
The system external controls and the
appliance must be supplied by the same
isolator.
6.12
Fig. 21
1. Take the 3 pin plug and lead assembly from
the gas fire contents kit and remove the 4 pin
electrical plug from the control PCB.
2. Remove the cover from the 4 pin plug and
E
undo the cable clamps (Fig. 22).
3. Route the mains inlet cable under the boiler
base through the cutouts (Fig. 23a).
IMPORTANT: The mains inlet cable MUST
Fire Cable
be routed under the boiler base to ensure
that it cannot interfere with the transformer
box on the fire front.
4. Connect the cables as indicated (Fig. 23):
Mains Inlet cable:
Fire cable:
Re-fit the cable clamps ensuring that the outer
insulation is securely held and re-fit the plug
cover.
Ensure that all cables are routed away from
the boiler casing and hood.
6.13
1. If not already done so, fit the boiler hood now.
Locate the flue within the flue socket and secure
with the three self tapping screws provided in
the kit.
2. Seal the flue against the flue outlet socket.
6.14
1. Seal off any secondary openings within the
builders opening after wrapping the gas and
water pipes through the brickwork and within the
opening itself. (B.S. 5871 Part 1).

Electrical Connection

to IEC Code 227 (heat resistant).
2

Making the Electrical Connection

Permanent live to L
Controls system switched live to SL
Control system neutral to N
Earth to
Brown (live) to L
Blue (neutral) to N
Green and Yellow (earth) to
Flue Connection (Fig. 24)

Completion

17

Advertisement

Table of Contents
loading