1.4. Error display

See the table below for descriptions of the displayed errors and countermeasures for these.
If multiple errors occur, only one item is displayed.
The priority order is w, e, r, t, y, q.
Condition
The model name, brand name and region information written in the firmware are compared
to the region settings in the PCB. This error is displayed if the information does not match.
q
" ▲ " is displayed as the first character if the firmware is not correct (see the illustrations on
Firm Check
the right).
NG
An error occurs in Loop back Test of the DDR memory which is performed during the initial
setting of i/p Scaler(ADV8003).
w
IP SCALER NG
During the initial setting of i/p Scaler ( ADV8003 ) , there is not the reply of the Loop back Test
result of the DDR memory .
If the Main CPU version is not supported by the GUI Serial Flash (ADV8003),
e
GUI Serial
" ▼ " is displayed as the first character of the GUI firmware version.
Flash NG
If GUI Serial Flash is damaged, " ▲ " is displayed as the first character.
r
This error is displayed if there is no response from the DIR.
DIR NG
Boot error 1 (After reset the DSP, DSP_Flag0 port is "Low")
Boot Error 2 (After reset the DSP, MCU received state error command)
Signal Detect Error (No response after input set for 1sec)
Mode Change Error (No response after mode change for 1sec)
t
DSP NG
Invalid situation (Detecting invalid situation with autodetect)
Busy Error ("Busy" port remains Low for 1sec)
Output Fs Error (Fs status between MCU output and actual DSP is different)
Input Fs Error (Fs status between AutoDetect Msg and ACCN Msg is different)
SPI communication error
y
Error occurred in BACKUP. it is an error of the check sum.
BACKUP NG
States
130
Display
FIRM ERROR
• Check the resistor for setting the region [R1524, 1525, DIGI-
TAL PCB].
M:*************
• Write the firmware for the correct region.
Main FBL :**.**
DSP#
:**.**
Audio PLD:**.**
Video PLD:**.**
• Check the circuits around the Logic[U1053] and
GUI
:********
SFROM[U1048]. If there appear to be no problems, [U1053]
PIMG
:********
or [U1048] is faulty.
• Check the circuits around the IP SCALER [U1026, DIGITAL
IP SCALER ERR 01
PCB] and DDR2 [U1028/U1029].
If there appear to be no problems, [U1026] or [U1028/U1029]
IP SCALER ERR 02
is faulty.
GUI VER. ERROR
• Check the firmware version.
GUI
:********
GUI
:********
• Check the DIR [U1040, DIGITAL PCB] and surrounding cir-
DIR ERROR 01
cuits.
DSP ERROR 01
DSP ERROR 02
DSP ERROR 03
DSP ERROR 04
• Check the DSP [U1073, DIGITAL PCB] and surrounding cir-
DSP ERROR 05
cuits.
DSP ERROR 06
DSP ERROR 07
DSP ERROR 08
DSP ERROR 09
BACKUP ERROR