5.3.THE COMPRESSOR NEVER
STOPS OR IT KEEPS
FUNCTIONING FOR A VERY LONG
PERIOD OF TIME
5.4.LIGHT DOES NOT WORK
TÜRKÇE
.Showcase is exposed to very high air
circulation
Thermostat settings are not done
correctly
Showcase is placed near a heating
object (stove, oven, etc.)
Front and back grills of the showcase is
blocked with an object (table, counter,
etc.)
Room temperature is too high (over 35C
or 95F)
Condenser is blocked with dust
Evaporator is blocked with ice
One of the fans may is not working
Leakage of gas
Sensors may be damaged
Thermostat is set to a very low
temperature (-30C/-22F)
The light button is turned off.
Fluorescent lamp is not connected
correctly.
Starter's burnt.
Fluorescent lamp's burnt.
Reactor's burnt.
ENGLISH
Change the place of the showcase if
there is too much wind and if the
showcase is very close to an A/C unit.
Call Technical Assistance.
Change the place of the showcase.
Either move the objects away from the
showcase or change the place of the
showcase.
Check Section 5.4. or Call Technical
Assistance.
Check Problems & Solutions 5.2.B.
Check Problems & Solutions 5.2.A.
Check Problems & Solutions 5.2.C.
Check Problems & Solutions 5.2.D.
Call Technical Assistance.
Check Section 7-FUNCTIONING.
Set the temperature according to the
values specified in Section 7.
Turn the light button ON.
Check Section 4.4. or Call Technical
Assistance.
Check Section 4.4. or Call Technical
Assistance.
Check Section 4.4. and change the
fluorescent lamp or call Technical
Assistance.
Check Section 4.4. or call Technical
Assistance.
24