SERVICE POSITION
The Basic Service Position does not require the use of Exten-
sion Cables. However, for more extensive servicing, Exten-
sion Cables should be used.
1. Basic Service Position
Service Position
Service Position (1)
Service Position (2)
Service Position (1)
1. Remove Rear Cover, VCR Unit, (Stereo Amp C.B.A.:
Model K), and Top Shield Plate Ass'y.
2. Then, place VCR Unit and (Stereo Amp C.B.A.: Model K)
as shown.
TV Main
C.B.A.
Stereo Amp C.B.A.
Insulated
(Model: K)
material
VCR Unit
Main C.B.A.
Fig. 2-1
Purpose
Mechanism check
Mechanical adjustment
Electrical adjustment
Main C.B.A. check
TV Main C.B.A. check
TV
It is not necessary to connect
Degaussing Coil Connector
Insulated material
Mechanism
Chassis and
Cassette Up
Ass'y
CAUTION:
HOT CIRCUIT
DO NOT
touch Power
circuit during service.
CAUTION:
HOT CIRCUIT
C.B.A. and TV Main C.B.A.
Use extreme care to prevent accidental shock when
servicing.
Note:
When disassembling/assembling, refer to "Disassembly/
Assembly Procedures of Cabinet" section.
Service Position (2)
1. Remove Rear Cover, VCR Unit, (Stereo Amp C.B.A.:
Model K), and Top Shield Plate Ass'y.
2. Place VCR Unit and (Stereo Amp C.B.A.: Model K) as
shown.
In order to stabilize VCR Unit, place it on a slanted support,
such as a loose-leaf binder etc.
Mechanism Chassis
and Cassette Up Ass'y
Main C.B.A.
VCR Unit
open
1-8
(Primary circuit) exists on the Main
CAUTION:
HOT CIRCUIT
DO NOT
Power circuit
during service.
It is not necessary to
connect Degaussing
Coil Connector
Stereo Amp C.B.A.
(Model: K)
Insulated material
TV Main C.B.A.
Fig. 2-2
touch
TV