5.1.11. WIRE AND LEAD POSITION DIAGRAM
Fig. 9
5.1.12. HOW TO SET TRACKING TO THE NEUTRAL POSITION
Ejecting the cassette tape and then reinserting it will reset the tracking to the Neutral position.
5.1.13. BLACK SCREWS ON THE CHASSIS
Black Screws are used on the Mechanism Chassis to identify screws that require adjustment.
5.1.14. HOW TO RESET ALL COMBINATION VCR MEMORY FUNCTIONS
To reset (clear) the select language, channel auto set and set clock functions to their initial
power on condition (power on, no cassette inserted), hold down the PLAY and FF buttons on the
unit together for more than 5 seconds.
Power will shut off.
5.1.15. HOW TO CONFIRM AUTO CLOCK SET FEATURE