System Options (Continued) - Linear ACP00937 Installation And Programming Instructions

Table of Contents

Advertisement

System Options (Continued)

Speaker Tone on Access Relay Activation
The factory setting will cause the speaker to sound a tone for two seconds
when the access relay is activated. Alternately, the tone can be turned
off.
1. Press
2. Select the option for access relay activation tone:
Enter 0 to turn OFF the access relay activation tone.
Enter 1 to turn ON the access relay activation tone.
3. Press
Maximum Visitor Talk Time
Visitors will converse with residents over the telephone until the resident
grants or denies access. If the resident responds to the visitor's request
by pressing their telephone key, the system will hang up and release
the telephone line. If for some reason the resident does not press
the telephone key or does not hang up, the system will automatically
disconnect the visitor after 60 seconds.
At ten and fi ve seconds before the disconnect, a tone will sound on the
telephone to remind the resident of the pending disconnect. The resident
can extend the talk time by pressing the # key on their telephone. The
disconnect time can be adjusted from 10-180 seconds.
1. Press
2. Enter the disconnect time in seconds (010-180):
3. Press
Resident Control of Access Relay
The factory setting allows the resident to activate the access relay by
pressing the 9 key on their telephone when a call from the AE-100 is
received. This feature can be disabled. Disabling this feature will only
allow access by using resident Entry Codes and Stand-alone Entry
Codes at the unit's keypad.
1. Press
2. Select the option for resident access relay control:
Enter 0 to turn OFF resident access relay control.
Enter 1 to turn ON resident access relay control.
3. Press
Resident Call-back
The resident call-back feature allows the AE-100 to answer the telephone
and switch to speakerphone mode if the telephone call is within
60 seconds of the last use of the AE-100. This feature gives residents the
capability to call a visitor back in case of a recently missed call.
This feature can only be used in single unit installations.
The factory setting disables the resident call-back feature. Alternately,
this feature can be enabled.
✦ NOTE: The Automatic Telephone Answer feature (PPN #61) must also be
enabled for the resident call-back feature to function.
1. Press
2. Select the option for resident call-back:
Enter 0 to turn OFF the resident call-back feature.
Enter 1 to turn ON the resident call-back feature.
3. Press
20
STANDARD PROGRAMMING METHOD
SPEAKER TONE ON ACCESS RELAY ACTIVATION
MAXIMUM VISITOR TALK TIME
RESIDENT CONTROL OF ACCESS RELAY
77#CONTROL#
CONTROL = 0 TO DISABLE RESIDENT CONTROL
CONTROL = 1 TO ENABLE RESIDENT CONTROL
FACTORY SETTING: RESIDENT CONTROL ENABLED
RESIDENT CALL-BACK
95#CALL-BACK#
CALL-BACK = 0 TO DISABLE RESIDENT CALL-BACK
CALL-BACK = 1 TO ENABLE RESIDENT CALL-BACK
FACTORY SETTING: RESIDENT CALL-BACK DISABLED
63#TONE#
TONE = 0 FOR ACCESS RELAY TONE OFF
TONE = 1 FOR ACCESS RELAY TONE ON
FACTORY SETTING: RELAY TONE ON
64#TIME#
TIME = TIME UNTIL AUTO-DISCONNECT
(010-180 SECONDS)
FACTORY SETTING: 60 SECONDS
PPN 63
PPN 64
PPN 77
PPN 95