f) Continuity test

Make sure that all the circuit parts, switches and components and other objects of
measurement are disconnected from the voltage and discharged.
• Turn the DMM on and select measuring function
.
• Press "MODE" button twice to switch measure-
ment functions. The symbol for continuity test
now appears in the display. Pressing this button
again takes you to the first measuring function
etc.
• Plug the red measuring lead into the V measuring
socket (9) and the black measuring lead into the
COM measuring socket (8).
• A continuity value of less than 50 Ohm is identi-
fied as continuity; in this case a beep sounds. The
impedance value is displayed up to 399.9 Ohm.
• If "OL" (overload) appears on the display, you
have exceeded the measuring range or the
measuring circuit has been broken.
• After measuring, remove the measuring lines from the measured object and turn the DMM off.