Group 15 Eppr Valve - Hyundai HX140L Manual

Table of Contents

Advertisement

GROUP 15 EPPR VALVE

1. PUMP EPPR VALVE
1)
COMPOSITION
EPPR (Electro Proportional Pressure Reducing) valve consists of electro magnet and spool valve
installed at main pump.
(1)
Electro magnet valve
Receive electric current from MCU and move the spool proportionally according to the specific
amount of electric current value.
(2)
Spool valve
Is the two way direction control valve for pilot pressure to reduce main pump flow.
When the electro magnet valve is activated, pilot pressure enters into flow regulator of main pump.
(3)
Pressure and electric current value for each mode
Mode
Standard
Option
2)
HOW TO SWITCH THE POWER SHIFT (STANDARD
You can switch the EPPR valve pressure set by selecting the power shift (standard
-
Management
Service menu
290F3CD149
Power shift (standard/option) : Power shift pressure can be set by option menu.
Pressure
kgf/cm
2
P
10
S
13
3
E
15
3
P
0
S
5
3
E
10
3
Enter the password
5-54
Electric current
(mA)
psi
142
330
189
40
365
218
40
400
0
160
73
40
250
142
40
330
OPTION) ON THE CLUSTER
290F3CD126
Engine rpm
(at accel dial 10)
30
1850
50
30
1750
50
30
1650
50
30
2100
50
30
2000
50
30
1750
50
option).
290F3CD150
290F3CD151

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents