Maintenance - Leister VACUUM PLATE 300 Operating Instructions Manual

Table of Contents

Advertisement

9. Maintenance

Warning
Dangerous voltage, danger to life from electric shock:
There are live components inside the device. Maintenance and repairs are to be carried out by
trained specialist personnel only.
Note
Avoid contact with aggressive substances (e.g. acetone, diluent, etc.). There is a risk of damage to
the installed components.
• Repairs must only be carried out by authorized Leister service centers.
• Clean cloths must be used to clean the device.
• Leister Service Centers guarantee a professional and reliable repair service within 24 hours with original spare
parts in accordance with circuit diagrams and spare parts lists.
You can find more information at
Recommended maintenance intervals for the device:
Period of time
(operating hours)
After each use of the
device
After each use of the
device
After each use of the
device
After each use of the
device
after approx. 300 h
14
www.leister.com
Monitoring and
maintenance work
Visual inspection of the
sealing lip for damage
Cleaning the sight glass
Visual inspection of the
filter plate for contami-
nation
Pressure adjustment
valve moves freely
Functional check of the
drive
Spare parts
Vacuum motor
Tools
Service
Water, clean cloth
Brush with plastic bristles
Service
Service