Pass Through Hookup

(Set Points Output to "PassThru")
This method runs the ignition trigger into and out of
the CT Series unit and allows for the most control,
however it requires more invasive wiring.
Connect pin 1 to 6-20v+ (Battery Positive).
Connect pin 4 to 6-20v- (Battery Ground).
Connect pin 6 to the trigger negative (mag-) wire from
the distributor or crank trigger.
Connect pin 7 to the trigger positive (mag+) wire from
the distributor or crank trigger.
Connect pin 8 to the points input or the mag trigger
positive wire. The points input is usually white on
most ignitions, and the mag + us usually the purple
wire going into the ignition box.
*Max Retard=35 deg
Note: The CT Series unit must be powered on for the
engine to run!
IMPORTANT: THE POINTS OUTPUT
MUST BE SET TO "PassThru" IN
THE ADVANCED MENU FOR PASS
THROUGH MODE.
27