Pioneer GEX-M7347XMZH/XN/UC Service Manual page 61

Xm satellite digital tuner
Table of Contents

Advertisement

1
Mode number
Mode name
A
ED
DIFF_ENS
EE
PC_UNDETECT
EF
SID_UNDETECT
F0
SCT_UNDETECT
F1
AUTH_MISS
F3
RAT_BLOCK
F4
RAT_LOW
F5
TOD_ROLLBACK
FF
REQ_RETRY
Display example: If the system is receiving, the display will momentarily show [M2_00_20].
B
4.12 ANTENNA PASS
No display.
If an antenna is not connected, and if this setting is made while the system is displaying the "ANTENNA" message,
connection checks will not be conducted until the system has been reset (the system will assume normal operation
without an antenna check).
4.13 QOS Message
Display format: [1AABBCCD].
C
A: The Bitabi error rate (two effective digits of decimal value) of terrestrial wave*1.
B: The Bitabi error rate (two effective digits of decimal value) of satellite wave 1*1.
C: The Bitabi error rate (two effective digits of decimal value) of terrestrial wave 2*1.
D: The quality of service (QOS) value (a single effective digit decimal value)*2.
*1: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will
show "-". For 100, the display will show "XX". If a signal is not received, the display will show "NS."
*2: The single digit display may show from 0 to 9. If the display information is being acquired, the display will
show "-". For 10 and over, the display will show "X".
4.14 TERR Message
D
Display format: [2ABBCCDD]
A: The locking status of the terrestrial wave*1.
B: The terrestrial wave Bitabi signal error rate (two effective digits of decimal value)*2.
C: The terrestrial wave Read-Solomon symbol error rate (two-effective digits of decimal value)*3.
D: The terrestrial wave Read-Solomon non-correction code word (two effective digits of decimal value)*4.
*1: The "-" will be displayed while the system is acquiring the information, "N" if the signal is not locked on, "D"
if only the demodulator is locked, and "T" if both the TDM and demodulator are locked on.
*2: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will
show "-". For 100, the display will show "XX". If a signal is not received, the display will show "NS."
*3: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will
show "-". For 100, the display will show "XX".
E
*4: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will
show "-". For 100, the display will show "XX".
F
50
1
2
Description
Specified Primary and Secondary PCID do not exist in an identical ensemble.
The PC signal of the specified program cannot be received.
SID of the specified program cannot be verified.
The service component type of the specified program cannot be verified.
Updating the encryption key.
Have not signed up for the charge service contract.
A program has been selected that is outside the range of the charge contract.
The time information, managed inside the DSP core and the time information
aired, do not match.
Failure occurred with the SSDEC (a restart is requested).
GEX-M7027XMZH/XN/UC
2
3
3
4