Summary of Contents for Vivreau Extra 85 HygienePlus VIV E 85 I-33-C2-HP-J
Page 1
VIVREAU EXTRA SERIES EN Operating manual...
Page 2
MF-838) and other health-hazardous exposed to the environment. Germs contaminants, such as cysts (in If a drain is not available only a VIVREAU waste container can be used. settle on the wet water tap, and without line with NSF 53). It also improves...
Page 3
SAFETY INSTRUCTIONS Important safety instructions. Please read these safety Observe the operating in- Make sure that the sticker • • instructions carefully before using the appliance. Keep structions for handling CO “Safety instruction for using the this manual in a convenient place so you can always refer to it compressed gas cylinders gas cylinder”...
Page 4
SAFETY INSTRUCTIONS the appliance immediately. Do state, and local codes. Place a tag on the Power Cord Consult the manufacturer even in • • not pull the plug out of the elec- Only trained and certified elec- to indicate that the unit has the case of a change of location.
Page 5
SAFETY INSTRUCTIONS gone training for the assigned following: Danger from insufficient tasks and has been instructed User The installation and initial com- • qualification of persons! on possible dangers caused by The user uses and operates the missioning of the appliance may Insufficiently qualified persons improper behavior.
Page 6
Danger through malfunction- Only use original spare parts ing safety equipment! • from VIVREAU or spare parts If safety equipment is not func- approved by VIVREAU. The tioning or is inoperative, there is device must be connected to...
Page 7
SAFETY INSTRUCTIONS If environmentally hazardous • substances are unintentionally released in the environment, immediately implement the ap- propriate measures. In case of doubt or as required by law or regulation, inform the respon- sible local authorities about the damages and inquire about suitable measures to be taken.
Page 8
Please observe the foldout page! WARNING! Safety instructions Use according to the intended purpose: Overview The water dispensers of the VIVREAU Make sure that the device I. VIVREAU Extra Tap System Used symbols TOP product range are solely designed is always sufficiently ventilated.
Page 9
After over 24h of nonuse, flush Set switch (6) to position O to switch the water dispenser thoroughly (see off. The switch light turns off. 1. Press VIVREAU button on the ‘Period of Inactivity’ on page 28). display. 2a. Press VIVREAU button once to activate the glass portion size.
Page 10
Errors and Warnings Standby All settings can only be executed by the operator or the service technician. I. VIVREAU Extra Tap System To enter the menu swipe downwards with two fingers on the display. A PIN code Error-Message: The display enters standby mode has to be entered.
Page 11
MENU STRUCTURE Only for operator or service technician Available water temperature setting modes Detailed information about the device: • • Coldest Device type • • Colder Device serial-no • • Cold Software version • Electronic hardware revisions Portion sizes Portion status Size A Size B (glass)
Page 12
SETTINGS MAINTENANCE Only for operator or service technician Portion Settings Temperature setting Schedule For the optimum and trouble-free If increased wear is identified during It is possible to preset two different portion sizes for The water temperature operation of the water dispenser, routine checks, the required intervals each water type.
Page 13
Empty drip tray Cleaning the housing Disinfecting the outlet tap Cleaning the cooling fins Check the CO bottle I. VIVREAU Extra Tap System WARNING! WARNING! 1. Remove the grille 1. Clean the dis- Danger to health Never cover up the cooling fins...
Page 14
REPLACING CO GAS BOTTLE Safety instructions for using CO gas cylinders. Not following these instructions may lead to serious or fatal injuries! 11 steps to change the CO cylinder safely: Always connect the CO cylinder to the WARNING! 1. CO bottle is empty.
Page 15
PERIOD OF INACTIVITY Before a period of inactivity longer than 3 days After a longer period of inactivity Before the water dispenser is due to experience a standstill of more than 3 days, After an inactive period longer than 24 hours or a power failure, clean dispensing proceed as follows: taps, housing and drip tray with antibacterial cloths and disinfectant spray, restore water supply and place a vessel on the drip tray and flush water dispenser with:...
Page 16
TROUBLESHOOTING Response to possible problems Problem Cause Remedy If problems occur, the dispenser will show relevant information and problem-solv- Water is warm Incoming water tempera- Make sure it is connected ing hints. If the problem cannot be solved immediately, please contact customer ture is too high to cold water service (see rear page).
Page 17
WHAT TO DO IN AN EMERGENCY Water leakage 1. Disconnect the 2. Shut off the water dispenser water supply from the power and collect the supply. leaked water. Refrigerant leakage WARNING! 1. Open doors Switch off the Danger to health 3.
Page 18
TECHNICAL DATA IDENTIFICATION PLATE VIVREAU Extra VIVREAU Extra 85 The identification plate is on the back of the appliance. Cooling Performance 22.5 gal/h Flow rate 0.5 gal/min Voltage 120 V Current, max. 4.1 A DISMANTLING AND DISPOSAL Power consumption, max.
Page 19
Vivreau USA 300 Roundhill Drive, Unit 2 Rockaway, NJ 07866, USA Telephone : 1 877 999 1044 E-Mail : servicena@vivreau.com www.vivreauwater.com Local Distributor / Dealer stamp 2021-12 1040530-01...
Need help?
Do you have a question about the Extra 85 HygienePlus VIV E 85 I-33-C2-HP-J and is the answer not in the manual?