A customizable base cabinet as technologies. The filter reliably If a drain is not available only a VIVREAU waste container can be used. accessory provides the option to install retains tested bacteria (acc. AST- it as a floorstanding system.
Page 3
SAFETY INSTRUCTIONS Important safety instructions. Please read these safety Observe the operating in- against falling. • instructions carefully before using the appliance. Keep structions for handling CO Make sure that the sticker • this manual in a convenient place so you can always refer to it compressed gas cylinders “Safety instruction for using the for the safe and proper use of the appliance.
Page 4
SAFETY INSTRUCTIONS the room thoroughly. Turn off in accordance with federal, Cord from Electrical Outlet. tored by trained personnel. the appliance immediately. Do state, and local codes. Place a tag on the Power Cord Consult the manufacturer even in • •...
Page 5
SAFETY INSTRUCTIONS a cloth immediately. following: Check the drip tray regularly Qualified person User The installation and initial com- • • and empty it if necessary. The qualified person has under- The user uses and operates the missioning of the appliance may gone training for the assigned water dispenser for the intended only be carried out by qualified...
Page 6
Only use original spare parts • If safety equipment is not func- from VIVREAU or spare parts tioning or is inoperative, there is approved by VIVREAU. The a danger of very severe injury or device must be connected to death.
Page 7
SAFETY INSTRUCTIONS If environmentally hazardous • substances are unintentionally released in the environment, immediately implement the ap- propriate measures. In case of doubt or as required by law or regulation, inform the respon- sible local authorities about the damages and inquire about suitable measures to be taken.
Please observe the foldout page! WARNING! Safety instructions Use according to the intended purpose: Overview The water dispensers of the VIVREAU Make sure that the device I. VIVREAU Top Tap System Used symbols TOP product range are solely designed is always sufficiently ventilated.
Page 9
Set switch (4) to position I to switch qualified person. on. The switch lights up. For the floorstanding version (coun- tertop + base cabinet) VIVREAU rec- ommends to mount the base cabinet to the wall. Please contact customer service for 1.
Errors and Warnings Standby All settings can only be executed by the operator or the service technician. I. VIVREAU Top Tap System To enter the menu swipe downwards with two fingers on the display. A PIN code The display enters standby mode has to be entered.
Page 11
MENU STRUCTURE Only for operator or service technician Available water temperature setting modes Detailed information about the device: • • Coldest Device type • • Colder Device serial-no • • Cold Software version • Electronic hardware revisions Portion sizes Portion status Size A Size B (glass)
SETTINGS MAINTENANCE Only for operator or service technician Portion Settings Temperature setting Schedule For the optimum and trouble-free If increased wear is identified during It is possible to preset two different portion sizes for The water temperature operation of the water dispenser, routine checks, the required intervals each water type.
Page 13
Empty drip tray Cleaning the housing Disinfecting the outlet tap Cleaning the cooling fins Check the CO bottle I. VIVREAU Top Tap System WARNING! WARNING! 1. Pull the drip tray (3) 1. Clean the stainless Danger to health Never cover up the cooling fins...
REPLACING CO GAS BOTTLE Safety instructions for using CO gas cylinders. Not following these instructions may lead to serious or fatal injuries! 11 steps to change the CO cylinder safely: Always connect the CO cylinder to the WARNING! 1. CO bottle is empty.
PERIOD OF INACTIVITY Before a period of inactivity longer than 3 days After a longer period of inactivity Before the water dispenser is due to experience a standstill of more than 3 days, After an inactive period longer than 24 hours or a power failure, clean dispensing proceed as follows: taps, housing and drip tray with antibacterial cloths and disinfectant spray, restore water supply and place a vessel on the drip tray and flush water dispenser with:...
Page 16
TROUBLESHOOTING Response to possible problems Problem Cause Remedy If problems occur, the dispenser will show relevant information and problem-solv- Water is warm Incoming water tempera- Make sure it is connected ing hints. If the problem cannot be solved immediately, please contact customer ture is too high to cold water service (see rear page).
Page 17
WHAT TO DO IN AN EMERGENCY Water leakage 1. Disconnect the 2. Shut off the water dispenser water supply from the power and collect the supply. leaked water. Refrigerant leakage WARNING! 1. Open doors Switch off the Danger to health 3.
Page 18
TECHNICAL DATA IDENTIFICATION PLATE VIVREAU TOP Series The identification plate is on the back of the appliance. VIVREAU Top 85 Cooling Performance 22.5 gal/h Flow rate 0.5 gal/min Voltage 120 V DISMANTLING AND DISPOSAL Current, max. 4.1 A Power consumption, max.
Page 19
Vivreau USA 300 Roundhill Drive, Unit 2 Rockaway, NJ 07866, USA Telephone : 1 877 999 1044 E-Mail : servicena@vivreau.com www.vivreauwater.com Local Distributor / Dealer stamp 2021-12 1040546-01...