| 2 | Operating Instructions | SMT500 Leak Detector Safety Precautions the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
SMT500 Leak Detector | Operating Instructions | 3 | en Specifications L x W x H 8 in. x 10 in.x 12.5 in. (20 cm x 25 cm x 33 cm) Weight 10.3 lb (4.5 kg) Shipping weight 18 lb (8 kg) Power supply 12 volts DC;...
| 4 | Operating Instructions | SMT500 Leak Detector Reference Guide 8. Fluid fill port • Turn counter clockwise to remove 1. Compound pressure gauge dipstick • Indicates amount of pressure or vacuum 9. External gas input • Allows for decay/leak down test to confirm •...
Page 5
SMT500 Leak Detector | Operating Instructions | 5 | en Accessories OEM-Approved Vapor- 169500005 Producing Fluid Vapor-producing fluid will perform over 1,000 typical tests (500+ per bottle) IMPORTANT: Contains no dye/contami- nants Schrader Valve Removal Tool 6522-5 EVAP Service Port Adapter...
| 6 | Operating Instructions | SMT500 Leak Detector Setup Testing for Leaks FILL/ADD VAPOR PRODUCING FLUID TESTING WITH SMOKE 1. Connect vapor output hose to system that is to be tested. See Diagnostics section for more detail. 2. Push vapor test button to begin a 5-minute...
Page 7
SMT500 Leak Detector | Operating Instructions | 7 | en Verify Repairs Diagnostics PERFORM DECAY / LEAK DOWN TEST Intake System and Vacuum Leaks 1. Pressurize the sealed system. This procedure will locate leaks in vacuum lines as well as manifolds, EGR valves, oil seals, 2.
Page 8
| 8 | Operating Instructions | SMT500 Leak Detector 5. Input vapor into the system through adapter. functions and other vacuum-operated systems. 6. Remove the fuel cap until dense vapor is 1. Disconnect the vacuum line, under the hood, exiting the filler neck.
SMT500 Leak Detector | Operating Instructions | 9 | en Maintenance Check Fluid Level 1. Remove fluid-fill plug from fluid fill port. 2. Pour OEM-approved vapor agent into fluid- fill port until fluid level is near top of the fluid-fill port.
| 1 0 | Operating Instructions | SMT500 Leak Detector Troubleshooting Problem Solution • Check polarity No green light • Ensure 12-volt battery is fully charged • Reconnect power cables • Power supply must be between 11.5 and 14 VDC Green light flashing •...
Page 11
SMT500 Leak Detector | Operating Instructions | 11 | en Notes SP01501467 | REV A | 4.2021 Bosch Automotive Service Solutions Inc...
Page 12
Bosch Automotive Service Solutions Inc Customer Service: 800-321-4889 Option 4, then 2 www.boschdiagnostics.com SP01501467 | REV A | 4.2021...