Spark Arrester - Honda FOURTRAX 350 4x4 2001 Owner's Manual

Table of Contents

Advertisement

01/04/28 16:44:00 3CHN5620_147

SPARK ARRESTER

The exhaust system must be periodically purged of accumulated
carbon.
To purge the system:
1.
Select a well-ventilated area free of combustible materials and
make sure the exhaust pipe is cool.
2.
Remove the bolt. (Fig.
3.
Start the engine and rev it up approximately twenty times while
momentarily creating exhaust system back pressure by blocking
the end of the muffler with a shop towel.
4.
Stop the engine and allow the exhaust pipe to cool.
5.
Reinstall the bolt securely.
(1)
Fig. 4-39
142
4-39
)
(1) Bolt

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trx 350 fm

Table of Contents