5
Power Terminals & Motor Connections
Power Terminals – E3 IP20
Size 1 – Mains supply - model dependant
200V single phase input
200V three phase input
400V three phase input
NOTE: Dynamic braking is not available
on size 1 drives
NOTE: For information on connecting
a braking resistor, see Section 15 –
Dynamic Braking
P a g e
| 8
Size 2, 3, 4 & 5 – Mains supply - model dependant
200V single phase
200V three phase
400V three phase
Optional
motor
earth
NOTE: On E3 size 4 & 5, there are earth
connections on the drives heatsink at
the top and bottom of the drive
Optidrive E3 Set-up Guide
Mains Supply
L1 L2/N L3
-DC
Control Terminals
+DC BR
U
V
W
Screen/
shielded
motor
Motor
cable