9.2 Wiring Diagram
CAUTION
Mark
MS
R.TH
TF
F
ER
POV
FR
W.TH
Figure 59: Wiring Diagram
EX08DT and EX11DT Installation and Operation Manual
Label all wires prior to disconnection when servicing controls. Wiring errors
can cause improper and dangerous operation.
Parts Name
Main Switch
Room Thermistor
Thermal Fuse
Fuse
Electrode
Modulating Solenoid Valve
Flame Rod
Wall Thermostat
Mark
Parts Name
OH.TH1,2 Over Heat Thermistor 1,2
OHS
Over Heat Switch
FM
Convection Fan Motor
SP
Sparker
SV1,2
Main Solenoid Valve 1,2
BL
Combustion Fan Motor
PS
Pressure Sensor
Code
Color
bk
black
bl
blue
gr/y
green/yellow
gr
green
r
red
w
white
y
yellow
gy
gray
or
orange
51