Page 2
The use of a trademark not shown below is not an indication that it is freely available for use. Windows® is a registered trademark of Microsoft Corporation. INSYS locks® is a registered trademark of INSYS MICROELECTRONICS GmbH. Publisher INSYS MICROELECTRONICS GmbH Hermann-Köhl-Str.
Page 3
TwinLock B670/C690 CashProtect DS Accreditations Accreditations EN 1300 / VdS 2396 M114307 High Security Lock Class EN B / 2 (TwinLock B) M114308 High Security Lock Class EN C / 3 (TwinLock C) G114106 TwinXT Closure monitoring – Class C G114107 TwinAlarm Closure monitoring –...
Definition of ‘Skilled Electrician’ ............12 Protection of the Environment ............12 System Description ................13 TwinLock B670/C690 CashProtect DS ..........13 TwinLock B670 CashProtect DS ............13 TwinLock C690 CashProtect DS ............13 3.3.1 System Diagrams ................. 14 3.3.2 Operating Unit QPad ................
Page 5
TwinLock B670/C690 CashProtect DS Table of Contents 4.6.1 Entering User- / Personnel Number ............33 User Groups ..................34 4.7.1 Operation with “User Groups” Selected ..........34 4.7.2 Selecting the Master / CIT master ............35 User Authorisation ................35 4.8.1 Fields and Boxes of the User Matrix .............
Page 6
TwinLock B670/C690 CashProtect DS Table of Contents 4.14.17 Resetting the Counter at the Lock (B Version only) ......64 4.14.18 Selecting User Groups ................65 4.15 Settings: Master ................66 4.15.1 Changing the Master Code ..............66 4.15.2 Registering PIN Code for Users ............67 4.15.3 Registering CIT Master Code ..............
TwinLock B670/C690 CashProtect DS General Information on This Manual General Information on This Manual Content and Usage This manual contains information on operation, configuration and maintenance of the electronic high-security lock system TwinLock B670/C690 CashProtect DS. There is a separate manual for other versions of system TwinLock CashProtect. The manual describes the procedures of the systems approved to comply with VdS- class 2 and 3 standards and also informs about the system settings.
TwinLock B670/C690 CashProtect DS General Information on This Manual Text Marks and Formatting 1.3.1 Safety Warnings Danger Imminent mortal danger / Danger of severe injuries / health hazard. Consequences which might arise from not being aware of the danger. Instructions on how to avoid the danger or remove its cause Warning Possibility of mortal danger / Danger of severe injuries / health hazard.
TwinLock B670/C690 CashProtect DS General Information on This Manual 1.3.2 Icons and their Meaning Use the operating unit. After some seconds without user input, the operating unit switches to idle mode. Tools are required. PIN code for users is required. Master code, PIN code for the master of the lock is required PIN code for the system manager code (manager code of lock).
TwinLock B670/C690 CashProtect DS General Information on This Manual 1.3.3 Operating Instructions Unmarked text following a headline of a paragraph with operating instructions contains information, which may be worth considering before performing the operating procedures described. Such text does not contain safety instructions. Take Text beginning with ‘Take’...
Assembly Instructions, may be performed by skilled electricians only (definition see p. 12), which have been trained and entitled to perform these jobs by INSYS MICROELECTRONICS or approved partner companies. Caution Danger of short circuit of electric components.
Make sure all other people are kept off the work area while such jobs are being carried out. Skilled electricians only, which have been instructed about the system by INSYS MICROELECTRONICS or a partner company and have been authorised by one of these companies, may perform jobs, which require the removal of the housing of units of the system or the modification of the hardware configuration.
As these persons do not have to be registered at the lock, the total number of users increases. Every system contains an operating unit, at least one lock INSYS Lock and a field bus distributor TwinConnect (small), which connects the components. All systems come with an instruction manual set.
Base System 1.1 consists of an operating unit, with option box RFID, as it may be, with a power adapter outside the protected premises, one INSYS Lock, one bus distributor TwinConnect, one blocking unit TwinXT and unit TwinIP inside the protected premises.
Page 15
TwinLock B670/C690 CashProtect DS System Description Fig. 2: System architecture of system 2.1 1) Two optional switches for both bolt mechanism and release switch The system 2.1 features two locks inside the protected premises. All other components are the same as those of system 1.1. Manual V.1.01B...
Page 16
TwinLock B670/C690 CashProtect DS System Description Fig. 3: System architecture of a system with TwinAlarm (example) 1) Burglar Alarm System (BAS) with input (Alarm contact, State contact, Arming) from ACE unit TwinAlarm and output (BAS-Ready, Disarm-Block, Acknowledgement, Release – No release, Power supply) to unit TwinAlarm 2) Optional bolt mechanism switch and switch for time program suspension Manual V.1.01B...
Lock INSYS Lock 700 Fig. 6: INSYS Lock 700 With lock INSYS Lock 700, you can lock and unlock the safe / container for valuables. The lock is located inside the protected premises. You can connect up to 2 locks / with C690 up to 3 locks to one system.
TwinLock B670/C690 CashProtect DS System Description 3.3.4 Bus Distributor TwinConnect / TwinConnect small Fig. 7: Bus distributor TwinConnect / TwinConnect small Via a redundant bus system, the bus distributor TwinConnect (small) connects the system components with each other. The bus distributor is located inside the protected premises.
TwinLock B670/C690 CashProtect DS System Description 3.3.7 Network Extension Unit TwinIP / TwinIP small Fig. 10: Network extension unit TwinIP / TwinIP small With optional network extension unit TwinIP (small), you can connect lock systems via network and protocol TCP/IP. 3.3.8 RFID cards / Tags / Bracelets Fig.
TwinLock B670/C690 CashProtect DS System Description 3.3.9 Survey: Codes in the System Fig. 12: Survey: codes in a sample system with TwinAlarm 1) Lock 1: mnemonic codes: 1 system manager code (manager code of lock 1) 1 master code 99 PIN codes for users 2) Lock 2: mnemonic codes: 1 master code...
TwinLock B670/C690 CashProtect DS System Description Overview of the Functions 3.4.1 Standard Functions Depending on the kind and the version of system TwinLock CashProtect, all or a part of the functions listed incomprehensively on this and the following page can be set before or after the installation.
Page 22
TwinLock B670/C690 CashProtect DS System Description Service functions Protocol with entries of up to 10,000 processes to trace back Im- / export of system configuration via USB System status display / feedback via colouring LED bar Reset of system components Display of versions of components Register / de-register components Motor test, one-step operation...
TwinLock B670/C690 CashProtect DS System Description 3.4.2 Further Functions (Setting via software) CashProtectPro is an optional PC software not included in the scope of delivery with which parameters of system TwinLock CashProtect can be set. Fig. 13: Start Page PC software CashProtectPro (sample) Among others, the following functions can be set with PC software: General Settings Automatic clock change to / from daylight saving time ON / OFF...
Page 24
TwinLock B670/C690 CashProtect DS System Description Time Programs Opening delay adjustable (0-99 min.) Release time adjustable (0-99 min.) 5 weekly programs with specific delays for each day of the week Special days program for blocking / opening for 24h 3 Part lock periods per weekday 10 Blocked - / Open periods Administration Functions Survey of all parameters...
TwinLock B670/C690 CashProtect DS System Description 3.4.3 Optional Functions The version of the firmware can be displayed via menu Status / Info. See page 52. Some of these functions can be programmed with the optional software CashProtectPro. For functions, which depend on network connection, the optional web-based software TwinNet is required.
Page 26
TwinLock B670/C690 CashProtect DS System Description Immediate blocking With the lock open or closed, you can program an immediate blocking for persons assigned to a week program via menu key . Once programmed, opening is blocked for all persons assigned to the week program during the currently active time window.
Page 27
TwinLock B670/C690 CashProtect DS System Description Closing: Automatic locking DS Option that the door contact of the operating unit makes the lock close automatically immediately after closing of the door / bolt work. Single-use code - / OTC functionality Section for the configuration of the use of flexible OTC / single-use code. Hotkeys You can define special certain keys of the operating unit as “hotkeys”.
TwinLock B670/C690 CashProtect DS Operation Operation With the operating unit, you can set and operate the system. Operating Unit QPad For system TwinLock C/B6X0 CashProtect, there is the membrane keypad version Fig. 14: Control elements of operating unit QPad 1) Keypad with numeric keys and, if required, letter-figures shift 2) LED bar (LED red: action erroneous / LED green: action successful) Enter key for confirming 4) Logo (LED red: not secured / LED green: secure / LED blue: parametrising mode)
TwinLock B670/C690 CashProtect DS Operation Hotkeys In addition to navigating the menus of the display of the operation unit, you can define keys 0-9 of the keys of the operating unit to become ‘hotkeys’ via CashProtectPro. If you press any of these hotkeys immediately after activating the display of the operating unit, the selected menu will be displayed right away.
With QPad, flexible OTC (single-use codes) can be generated as QR codes. These QR codes can be read via the optional app ‘locksAppCIT’ by INSYS locks. Via command “Request code”, the codes can be displayed as single-use codes (with digits) again.
TwinLock B670/C690 CashProtect DS Operation The System Status and Mode 4.5.1 The System Status System settings can be modified and changed with the system unlocked. Only menus Open, Close and Status / Info are on display on the operating unit with the system locked. In order to unlock the system, - open lock 1 (with option ‘Forced sequence’...
TwinLock B670/C690 CashProtect DS Operation 4.5.3 Pairing Only with firmware version 25/26 and higher. "Pairing" is a procedure that ensures that the communication between and QPad, the locks and, as it may be, TwinIP is encrypted and that these units cannot be exchanged without authorisation. See „Setting Up “Pairing”“on p.
TwinLock B670/C690 CashProtect DS Operation User- / Personnel Numbers Via user matrix of the optional PC software, the system can be configured in such a way that users can enter the personnel number they are used to instead of entering user numbers specific for the system.
TwinLock B670/C690 CashProtect DS Operation User Groups Optional with special licence with B670. The users stored at the locks of every system can be divided into two groups: The system manager activates this option via menu „User groups“ of the display of the operating unit.
TwinLock B670/C690 CashProtect DS Operation 4.7.2 Selecting the Master / CIT master Lock - and CIT master select ‘Master’ / ‘CIT master’ before entering code: As master / CIT master, follow the steps of an instruction until code input is required.
TwinLock B670/C690 CashProtect DS Operation 4.8.1 Fields and Boxes of the User Matrix The user matrix can be displayed and edited, as the case may be, via PC software. Caution Users cannot open locks in case they have not been authorised sufficiently.
TwinLock B670/C690 CashProtect DS Operation WP1 – WP5 If boxes are marked, the Weekly Programs selected are assigned to users. These users can open during opening periods defined in the Weekly Programs only. Language Optional user specific language setting, not available Personnel no.
TwinLock B670/C690 CashProtect DS Operation 4.8.3 Authorisation of Manager / Master / User / etc. Survey of authorisation of manager (no.225), master (no.00), user (no.01-99), and, as it may be, CIT master / master group 2 (no.99) in the QPad menu structure. Description of standard settings, can partly be changed via user matrix.
TwinLock B670/C690 CashProtect DS Operation Menu Structure of Operating Unit (with system open, all menus of all systems) System menu with display Mo 11.10.21 8:35 Open Close Arming (optional) Status / Info Settings – Manager – Change code └─ Master Register –...
TwinLock B670/C690 CashProtect DS Operation 4.10 PIN Codes Caution The system is not protected with ex works versions of system manager – and master code. Danger of unauthorised opening. Due to security reasons, change the ex works versions of codes as soon as possible.
TwinLock B670/C690 CashProtect DS Operation 4.10.2 Entering PIN Code Depending on the type / configuration of the system, users enter personal PIN / PIN code with the following keys: With locks of VdS class 2 / B, optional with numerical keys or with menu keys (setting via PC software / TwinNet).
TwinLock B670/C690 CashProtect DS Operation 4.11 RFID Cards Optional RFID Cards can be registered by the master only. At every lock, RFID cards can be registered and deregistered for up to 99 users. RFID cards can contain user code, as it may be. Ex works, the card codes for users no.01 – no.99 are inactive. See section „User Authorisation“.
TwinLock B670/C690 CashProtect DS Operation 4.12 Opening and Closing Depending on the configuration of the lock system, users enter their user – or their personnel number (“staffnb”) before entering code. Mostly, only one of these options is described within the following sets of instructions. Caution If a burglar alarm system (BAS) is connected to the system, users cannot open lock 1 unless they are authorised to...
TwinLock B670/C690 CashProtect DS Operation 4.12.2 Opening a Lock with a RFID Card Settings Boxes Card, Release, (1 of x), Open locks and, if required, Disarm of the user matrix have been marked for you. The lock master has registered a code card at the lock for you. Take an optional RFID card.
TwinLock B670/C690 CashProtect DS Operation 4.12.3 Triggering Silent Alarm When Opening a Lock That is an inconspicuous way to send a message calling for help. The alarm cannot be triggered via RFID card. When entering PIN code, trigger the alarm by carrying out the steps listed below. Settings You have been authorised to open via PIN and, as it may be, to arm the burglar alarm system (BAS).
TwinLock B670/C690 CashProtect DS Operation 4.12.4 Opening a Lock with Dual Code Only if both of the two participating users carry out all kinds of authentication assigned to them, the lock will open. Settings The option ‘Dual code (Opening)’ is activated. Press key Clear and release it after immediately, and, if required, press key >...
TwinLock B670/C690 CashProtect DS Operation 4.12.6 Opening with Unlocking Delay and Release Time This paragraph is a sequel of the last one. Settings See the last paragraph. Additionally, option ‘Release time’ is activated. Perform steps 1-5 of the last paragraph and be prepared to enter code when indicated.
TwinLock B670/C690 CashProtect DS Operation 4.12.8 Opening with OTC Flexible Also see „Operation with OTC Flexible“ on page 30. With the conditions fulfilled, users can open locks ● (with personnel number,) with RFID card and OTC flex or ● with personnel number, with personnel PIN and OTC flex. Settings see „Conditions for OTC Flexible “on page 30.
TwinLock B670/C690 CashProtect DS Operation 4.12.10 Closing a Lock When the lock locks after having been opened via OTC, a 4-digit return code CIT code: XXXX (optional QR code) is displayed upon the operating unit. This code can be passed on via telephone, for example, and it can be used by the person in charge to end the process.
TwinLock B670/C690 CashProtect DS Operation 4.12.12 Closing a Lock Automatically with the Door Switch This option can be set via optional PC software. Settings TwinXT or TwinAlarm are connected and activated. On tab ‘Settings’ of CashProtectPro, for example, option ‘Automatic closing with door switch’...
TwinLock B670/C690 CashProtect DS Operation 4.12.14 Arming a Burglar Alarm System (BAS) Depending on the setting in the PC software (‘Settings / Alarm / TwinAlarm / Arming with code card’ On / Off, for example), users either enter PIN code or insert their code card to arm the BAS or they do not have to do so.
TwinLock B670/C690 CashProtect DS Operation 4.13 Hidden Menu, Status, Network 4.13.1 Displaying the Hidden Menu Certain basic settings can be made or verified via the hidden menu. Every user can display the hidden menu. The system manager code is required for certain settings (language import, setting the time, configuring the alarm devices and the network).
TwinLock B670/C690 CashProtect DS Operation 4.13.3 Connecting the Lock with the Network Set the server address via browser of the client PC: Enter address ex works 192.68.1.1 into the address line of the browser, enter name „twinnet“ and password „twinnetsetup“ in pop-up window, select button OK and enter the server address in box „Server address“...
TwinLock B670/C690 CashProtect DS Operation 4.14 Settings: Manager 4.14.1 Changing the System Manager Code The system manager code of the lock (= system code) does not enable its holder to open the lock, but to configure the system. Currently (10/2021), the changed code is not copied to lock 2 automatically.
TwinLock B670/C690 CashProtect DS Operation 4.14.2 Registering Master Code The manager can register master code. The master / holder of the master code can administer users saved within the lock and can register the CIT master. Also see “Registering PIN Code“. Unlock the system by opening lock 1 or by opening all locks.
TwinLock B670/C690 CashProtect DS Operation 4.14.3 Deregistering Master Code The manager can deregister master code. Caution Danger of loss of functions. Possibly users stored at the lock cannot be administered anymore. Make sure there is no loss of functions. Select Manager | Master. Master | Register is on display.
TwinLock B670/C690 CashProtect DS Operation 4.14.5 Setting the Date and the Time of Day All the time-based functions and the correctness of the protocol depend on the proper setting of date and time. Clock change (daylight saving time) in spring and autumn is automatic with this option selected.
TwinLock B670/C690 CashProtect DS Operation 4.14.7 Parallel Code Optional selection of Parallel code for lock systems with 2 locks (at least). The first user can open lock 1, 2 or 3, the second user opens the other lock or one of the two locks still closed and the third, if required, closes the last lock.
TwinLock B670/C690 CashProtect DS Operation 4.14.11 Alarm Devices: XT Extension / TwinAlarm Caution Risk that „No release“ is displayed upon an attempt at opening the lock after the activation of the extension unit. After activating the extension unit, both inputs are active.
TwinLock B670/C690 CashProtect DS Operation 4.14.12 Setting Up “Pairing” The manager can set up “Pairing”. Also see „Pairing“, page 32 and the manual TwinIP, as it may be. Attention: The pairing key is not the AES key used for the installation of the system IDs.
TwinLock B670/C690 CashProtect DS Operation 4.14.13 Setting Up “Code Distribution” With TwinNet 10.3 and higher only. Also see „Code Distribution“, page 32 and the manual TwinIP. Settings Network connection, TwinIP and pairing set up correctly Unlock the system (open lock 1 or all locks). With >...
TwinLock B670/C690 CashProtect DS Operation 4.14.14 Single Access (Flexible OTC, Test Function) The manager can test with this function whether the settings for flexible OTC work properly. Also see „Conditions for OTC Flexible“ on page 30. The function is available only in case - all conditions for flexible OTC are met and - an alarm device has been activated - flexible OTC has been created for the user via TwinNet / MultiPad Go!
TwinLock B670/C690 CashProtect DS Operation 4.14.15 System ID A/B The manager can install the system IDs A and B. Doing this is one condition for the operation with flexible OTC (one time codes, single-use codes). See section “Operation with OTC Flexible” on p.30. The system detects the kind of ID.
TwinLock B670/C690 CashProtect DS Operation 4.14.16 Defining the Mode / CIT Function (B Version only) The manager can define the mode / the CIT function. Also see Mode / CIT Function, p. 31. Unlock the system by opening lock 1 or by opening all locks. Select Settings with key >...
TwinLock B670/C690 CashProtect DS Operation 4.14.18 Selecting User Groups May be available with special license only. Define whether the users stored at locks are assigned to two user groups and are administered separately or whether that should not be the case. Before activating the option, register the CIT master.
TwinLock B670/C690 CashProtect DS Operation 4.15 Settings: Master 4.15.1 Changing the Master Code Holders of the master code of the lock (lock master) can administer the users of the lock and, optionally, they can open the lock. Caution With the master code in ex works version, your system is not protected.
TwinLock B670/C690 CashProtect DS Operation 4.15.2 Registering PIN Code for Users The holder of the master code of the lock (lock master) can register PIN codes. Only masters with right “Service” can assign week programs with PIN code (see below). Users / persons have to be authorised to lock opening with PIN code.
TwinLock B670/C690 CashProtect DS Operation 4.15.3 Registering CIT Master Code Settings Parameter „User groups“ has not been selected yet. The system manager selects that parameter after the master has registered PIN code for user no. 99 like described here. Upon that, this user turns CIT master. Follow the steps of paragraph “Registering PIN Code for Users“...
TwinLock B670/C690 CashProtect DS Operation 4.15.4 Deregistering PIN Code for Users The holder of the master code (lock master) can deregister PIN codes. With option „User groups | * = YES selected, the CIT master can also do Caution Danger of a configuration error: Opening the lock might become impossible.
TwinLock B670/C690 CashProtect DS Operation 4.15.5 Displaying User PIN Codes The lock master and, as it may be, the CIT master can display for which users PIN codes have been registered. With CIT operation (2 user groups), master and CIT master can administer and display their range of users only. Select menu Settings | Master | PIN code.
TwinLock B670/C690 CashProtect DS Operation 4.15.6 Registering Code Cards (RFID Cards) The lock master and, as the case may be, the CIT master, can register code cards for themselves and for other users. In order to be able to use the card to identify themselves, users must be authorised to do so.
TwinLock B670/C690 CashProtect DS Operation 4.15.7 Deregistering User Code Cards The lock master can deregister code cards TwinCard code access. Even a user authorised to open with card cannot open the lock with a deregistered card. Caution Danger of a configuration error: Opening the lock might become impossible.
TwinLock B670/C690 CashProtect DS Operation 4.15.8 Displaying User Code Cards The lock master and, as it may be, the CIT master can display for which users cards have been registered. With CIT operation (2 user groups), master and CIT master can display their range of user cards only. Select menu Settings | Master | Code card.
TwinLock B670/C690 CashProtect DS Operation 4.16 Settings: Employees 4.16.1 Changing User PIN Code All employees / users can change their PIN codes. Settings You have been authorised for opening with PIN code. The lock master has registered PIN code at the lock for you.
TwinLock B670/C690 CashProtect DS Operation 4.17 Service Descriptions of the functions of menu Service. Also see „Menu Structure of Operating Unit“ on page 39. 4.17.1 Reset: Loading the Factory Settings of the Terminal Note: Loading the factory settings deletes the user- and configuration settings. Caution By reloading the factory settings, system specific settings concerning hardware and user settings...
Page 76
TwinLock B670/C690 CashProtect DS Operation 12. Enter the system manager code again. Serial no. | Please wait is on display. The serial number of the operating unit is saved in the lock. Serial no. | Saved is on display. With more than one locks in the system Serial no. | Lock 2 and Code entry | Manager and Code: are on display.
TwinLock B670/C690 CashProtect DS Operation 4.17.2 Reset: Delete Lock User Codes Note: Deleting the lock codes deletes the user- and the master code. Lock address and manager code remain unchanged. Unlock the system (open lock 1 or all locks). With > and Enter, select Service. Service | Reset is on display.
TwinLock B670/C690 CashProtect DS Operation 4.17.3 Motor Step Lock masters can examine the bolt movement by moving the bolt of the lock step by step in both directions with menu Motor step. Note If ‘automatic closing’ is set via optional PC software, the system will close the lock one minute after the end of the motor steps described here.
TwinLock B670/C690 CashProtect DS Operation 4.17.4 Registering a New Lock The system manager can register a new lock in the system or replace an existing lock via menu Regist. new lock. Only new locks that have never been addressed before can be registered via menu Service | Regist.
TwinLock B670/C690 CashProtect DS Operation 4.17.4.2 Changing Locks is the sequel of „Registering a Lock“ in case you replace a lock, but do not extend the system by adding a new lock. Also see „Additional Lock“ above. Follow the steps 1-4 of paragraph „Registering a Lock“. Regist.
Function no: 01 + License code -> to activate menu “user groups”. Function no: 07 + License code -> to activate TwinLock B650 CashProtect. Function no: 08 + License code -> to activate TwinLock B670 CashProtect DS. Licensing: FF is displayed in case of an error.
TwinLock B670/C690 CashProtect DS Operation 4.18 Import / Export Options with menu Import / Export. USB is used for im- / export. 4.18.1 Importing Configuration and Language Settings You have manager rights. Take Connection via USB available; see p. 29; port / interface set up via CashProtectPro.
TwinLock B670/C690 CashProtect DS Operation 4.18.2 Messages During Configuration Import During the import of a configuration the error messages listed below may be on display in the second display line. The display features two lines. Config. error in the first line indicates that an invalid value has been allotted to a parameter.
TwinLock B670/C690 CashProtect DS Operation 4.18.3 Exporting and Printing configuration and Protocol Settings Boxes Release, Service and PIN code of the user matrix have been marked for you / you have the rights of a master / manager. Take Connection via USB available; see p.29; Set up port / interface via CashProtectPro.
TwinLock B670/C690 CashProtect DS Operation 4.18.4 Selecting a Language Every user can choose between three languages in case the languages have been stored within the operating unit before. Press Clear and release the key immediately. Date and time are on display, Mo 11.10.21 15:50, for example. Press key Enter and keep the key depressed.
Observe the bolt work maintenance interval recommended by the manufacturer of the bolt work. Repair tasks are to be performed solely by skilled electricians (see definition on page 12) trained and authorised by INSYS NICROELECTRONICS or partner companies. Caution Danger of short circuit of the electronic components.
TwinLock B670/C690 CashProtect DS Trouble Shooting Trouble Shooting Supplying Power in Case of Power Breakdown Manufacturers of batteries offer fitting 9V block batteries like 6LR61 (alkaline type), 6F22 (zinc-carbon), 6AM6, 522. Take an adapter cable (included in system delivery) and a loaded 9 V block battery.
Page 88
TwinLock B670/C690 CashProtect DS Trouble Shooting Close&Code User has not been authorized to close locks by entering his code. ✓ Consult your system manager. See above. Code card User has not been authorized to use a code card. ✓ Consult your system manager. See above. Disarm BAS User has not been authorized to disarm a burglar alarm system.
Page 89
TwinLock B670/C690 CashProtect DS Trouble Shooting Disarming error TwinAlarm signals an error during disarming the burglar alarm system (BAS): BAS cannot be disarmed because it does not acknowledge being disarmed. ✓ Contact staff with expert knowledge in alarm technology / technical support to have the connection to the BAS checked.
Page 90
TwinLock B670/C690 CashProtect DS Trouble Shooting Error TwinAlarm An error occurred in the communication with TwinAlarm. ✓ Repeat the task you tried to carry out before the message was displayed. Contact technical support if the message is displayed once more. Invalid card The code card is invalid.
Page 91
TwinLock B670/C690 CashProtect DS Trouble Shooting No release! Opening is not possible. Lock has not been enabled via input contact RELEASE of TwinXT / TwinAlarm. ✓ Check whether TwinXT / TwinAlarm are connected properly and whether the lock should be blocked or not. Contact technical support, if the error message is displayed again.
Page 92
TwinLock B670/C690 CashProtect DS Trouble Shooting Trivial code A user has entered code, which contains a row of ascending or descending numbers (12345…/ 76543...). ✓ Such code may be forbidden for security reasons. Enter another code. Was currentless The system has been without power supply. The display of the message ends at the time a lock is opened.
Phone: +49 9104 82622-0 Fax: +49 9104 82622-22 E-mail: anfrage@fmr.ag Internet: http://www.frankenberg-metallhandel.de Please label locks ‘zur Entsorgung / to be disposed of’ and send them to the following address: INSYS MICROELECTRONICS GmbH Herman-Köhl-Str. 22 D 93049 Regensburg, Germany Manual V.1.01B...
TwinLock B670/C690 CashProtect DS Glossary Glossary Terms like Alarm code, printed in bold letters, also are headings of entries of this glossary. In order to make reading easy, only selected terms, which are important in the context they stand, are printed bold. Read the entries for these terms also. Parameters that can be set via the optional software CashProtectPro for systems, in general also can be set via the optional, net based software TwinNet.
Page 96
TwinLock B670/C690 CashProtect DS Glossary Blocked period / open period (time program) A blocked period is a time span of one day up to a year during which the system cannot be opened. Via software CashProtectPro (optional accessory), you can define up to three blocked periods.
Page 97
TwinLock B670/C690 CashProtect DS Glossary • configuring the system, • closing / locking locks or • entering code during release time is possible only after two users have proved their authorisation at the lock. 4-eye principle (Opening) cannot be selected simultaneously with Parallel code. Selected users can be authorised to be able to open locks without a second person even with option ‘Dual code’...
Page 98
TwinLock B670/C690 CashProtect DS Glossary For every lock there is exactly one master code assigned to user no. 00 (lock master). This code can be stored in the lock. With it, lock users can be administered. Ex works the master code for locks of VdS class 2 is ‘123456’ and for locks of class 3 it is ‘12345678’.
Page 99
TwinLock B670/C690 CashProtect DS Glossary Power breakdown Power is supplied to the system via a power pack connected to TwinConnect. In order to be able to open and close locks even when a power breakdown has occurred, connect a 9 V battery (alkaline or zinc-carbon type) to the operating unit. Plug the adapter cable into the socket at the bottom of the operating unit.
Page 100
TwinLock B670/C690 CashProtect DS Glossary Special days are days on which opening locks is impossible during the whole day (with all versions). Every attempt at opening a lock on a special day is aborted. You can define up to 30 special days in a year via optional software. ‘Special days’ can be marked as ‘annually recurring’...
Page 101
TwinLock B670/C690 CashProtect DS Glossary User groups Caution Without a CIT master sufficiently authorized, the CIT user group cannot be administered. Authorise user 99 sufficiently (see chapter ‘Operation’, paragraphs ‘Authorising the Users’ and ‘Operation with “User groups” Selected’) before you select “User groups”. With option ‘User groups’...