READ THIS MANUAL CAREFULLY
BEFORE USING THE SPECK PUMP
NOTE: All wiring should be done by a qualified electrician in accordance with the National Electrical Code and all Local Codes.
NOTE: Before installation, inspect all equipment, plumbing and wiring for damage that may have occurred during shipment.
The shipping container has been specifically designed to prevent damage, however, any indications of damage should be
carefully noted on the delivery ticket and a claim needs to be filed with the carrier.
All pumps are water tested on a test stand to ensure that they meet specification.
SECTION 1 IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment,
basic safety precautions should always be followed,
including the following:
WARNING - To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.
WARNING - Risk of Electric Shock. Connect only
to a branch circuit protected by a ground-fault
circuit interrupter (GFCI). Contact a qualified
electrician if you cannot verify that the circuit is
protected be a GFCI.
WARNING - To reduce the risk of electric shock,
replace any damaged cord immediately.
Do not install within an outer enclosure or beneath
the skirt of a hot tub or spa.
CAUTION - This pump is for use with
permanently-installed pools and may also be used
with hot tubs and spas if so marked. Do not use
with storable pools. A permanently-installed pool is
constructed in or on the ground or in a building
such that it cannot be readily disassembled for
storage. A storable pool is constructed so that it is
capable of being readily disassembled for storage
and reassembled to its original integrity.
SECTION 2 WINTERIZING
In areas subject to freezing winter temperatures,
protect by removing drain plugs. Do not replace plug.
Store plug in strainer basket for winter.
The unit must be connected only to a supply circuit
that is protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the
installer and should be tested on a routine basis. To
test the GFCI, push the test button. The GFCI
should interrupt power. Push the reset button.
Power should be restored. If the GFCI fails to
operate in this manner, the GFCI is defective. If the
GFCI interrupts power to the pump without the test
button being pushed, a ground current is flowing,
indicating the possibility of an electric shock. Do
not use this pump. Disconnect the pump and have
the problem corrected by a qualified service
representative before using.
TO
REDUCE
SHOCK, A copper bonding connector (8 AWG) is
provided for bonding the motor to all metal parts of
the swimming pool, spa, or hot tub structure and to
all electrical equipment, metal conduit, and metal
piping within 5 feet of the inside walls of a
swimming pool, spa, or hot tub, when the motor is
installed within 5 feet of the inside walls of the
swimming pool, spa, or hot tub.
NOTE: To installer and/or operator of the Speck
Swimming Pool Pump; the manufacturer's waranty
will be voided if the pump is improperly installed
and/or operated.
9.
An alternative is to remove the pump and motor from
plumbing and store indoors in a warm and dry location.
RISK
OF
ELECTRICAL

Advertisement

loading

Summary of Contents for Speck pumps S90

  • Page 1 OWNER’S MANUAL Swimming Pool Pump READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP NOTE: All wiring should be done by a qualified electrician in accordance with the National Electrical Code and all Local Codes. NOTE: Before installation, inspect all equipment, plumbing and wiring for damage that may have occurred during shipment. The shipping container has been specifically designed to prevent damage, however, any indications of damage should be carefully noted on the delivery ticket and a claim needs to be filed with the carrier.
  • Page 2 To replace the mechanical seal, remove the eight bolts used as a lubricant to mount both parts of the mechani- seal. holding the casing to the seal housing. Slide the motor p art including the seal-housing out. Remove impeller RE V . 0411 - Model S90 2999999927...
  • Page 3 The serial number is located on the Speck Call, fax, or write: Speck Pumps - Pool Products, Inc. • 8125 Bayberry Road • Jacksonville, FL 32256 Phone (904) 739-2626 • Fax (904) 737-5261 • email: info.usa@speck-pumps.com SECTION 6 TROUBLESHOOTING GUIDE...
  • Page 4 Date of Ins t allation ___________________ _ Ins t alled By _________________________ _ For Service Call _______________________________ _ RE V . 0411 - Model S90 2999999927...