Use Of The 40 Kva Distributor; Measuring Device - Wieland gesis Manual

System distributor for temporary electrical installations
Table of Contents

Advertisement

9.2

Use of the 40 kVA distributor

To make full use of 40 kVA, both a 40 kVA and a 20 kVA installation distributor is required. The 40 kVA
is fully available due to forwarding and symmetrical load distribution to both installation distribu-
tors.
The two installation distributors can thus be operated as follows:
• spatially separated, e.g. on an exhibition stand with 40 kVA
• for supplying e.g. two exhibition stands with 20 kVA each
The 40 kVA installation distributor can also be operated stand-alone with a corresponding adapter
on a 20 kVA connection. In this case max. 20 kVA is available
9.3

Measuring device

If your installation distributor has a measuring device, it must be put into operation. Please read the
operating instructions of the manufacturer's measuring device.
The recommissioning (e.g. resetting RCD) can be carried out by trained laypersons.
NOTE
Wieland Electric GmbH | BA001281 | 04/2022 (Rev. A)
Operation
22

Advertisement

Table of Contents
loading

Related Products for Wieland gesis

Table of Contents