Fig. 49: Fitting The Gas Inlet Casing (A175-L And Smaller) - Threaded Stud Variant; Table 35: Tightening Torque (51087) - ABB HT844414 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
8 Disassembly and assembly / 8.10 Fitting the gas inlet casing, the
nozzle ring and the insulation (A175-L and smaller)
Fitting the gas inlet casing (A175-L and smaller) - threaded stud variant
Fig. 49: Fitting the gas inlet casing (A175-L and smaller) - threaded stud variant
Part number
51087
Table 35: Tightening torque (51087)
1) Pre-tightening torque of the nuts
1. Coat threaded stud (51086) with high-temperature grease, screw in up to the stop in the
gas outlet casing (61001) and tighten hand-tight.
2. Loop around the gas inlet casing (51001) with the lifting gear and secure it to the crane.
3. Push gas inlet casing over the threaded studs up to the gas outlet casing.
4. Coat two nuts (51087) with high-temperature grease and fix gas inlet casing in two op-
posite positions.
5. Coat remaining nuts with high-temperature grease, fit and then tighten crosswise, ini-
tially to the pre-tightening torque and then to the tightening torque.
6. Remove the lifting gear.
7. Connect the flange of the gas inlet casing and the bellows.
© Copyright 2018 ABB. All rights reserved.
A165-L
M16
1)
30
 Nm
140 Nm
HZTL4034_EN
A170-L
M18
1)
40
 Nm
200 Nm
Revision N
A175-L
M22
1)
50
 Nm
380 Nm
November 2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

A170-l37

Table of Contents