Electrical Adjustments - Sony SS-DP1000D Service Manual

Mini hi-fi component system
Table of Contents

Advertisement

HCD-DP1000D
SECTION 5

ELECTRICAL ADJUSTMENTS

DECK SECTION
0 dB=0.775 V
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Tape
Signal
P-4-A100
10 kHz, –10 dB
WS-48B
3 kHz, 0 dB
P-4-L300
315 Hz, 0 dB
Record/Playback Head Azimuth Adjustment
DECK A
DECK B
Note: Perform this adjustments for both decks
Procedure:
1. Mode: Playback
test tape
main board
P-4-A100
CN301
(10 kHz, –10 dB)
Pin 3 (L-CH)
Pin 1 (R-CH)
set
main board
CN301
Pin 2 (GND)
18
Used for
Azimuth Adjustment
Tape Speed Adjustment
Level Adjustment
level meter
+
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
within
L-CH
1dB
peak
Output
level
R-CH
peak
Screw
position
L-CH
peak
3. Mode: Playback
test tape
P-4-A100
(10 kHz, –10 dB)
pin 3
L-CH
MAIN
L
board
CN301
R
set
R-CH
pin 1
waveform of oscilloscope
in phase 45 °
good
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
reverse
forward
within
1dB
Screw
position
R-CH
peak
oscilloscope
pin 2
V
H
90 ° 135 ° 180 °
wrong

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss-dp1000dwHcd-dp1000dSs-rc270Ss-rs270Ss-ct270

Table of Contents