External static pressure
When using the wireless remote controller
To set up the external static pressure, use the DIP switch on the circuit board of the wireless reception part.
For details, refer to the instruction manual of the wireless remote controller kit. Alternatively, use the switch on the
indoor micro computer circuit board as shown in the following figure and table.
* Once switched, the settings "0001", "0003", and "0006" can be changed, but to reset to "0000", you need to set
the switch to the normal (default) position and use a separately-sold wired remote controller to overwrite the data
with "0000".
SW501
41-EN
SW501-1
OFF
ON
OFF
SW501-2
OFF
OFF
ON
SET DATA
0000
0001
0003
To reset to the factory default
Switch off SW501-1 and SW501-2, connect a separately-sold
wired remote controller, and then perform the procedure for
installing a separately-sold filter on this page to set the [5d]
data to "0000".
– 21 –
 Filter sign setting
According to the installation condition, the filter sign
term (Notification of filter cleaning) can be changed.
Follow to the basic operation procedure
1
2
3
4
5
(
• For the CODE No. in Procedure
• For the [SET DATA] in Procedure
DATA of filter sign term from the following table.
SET DATA
ON
0000
ON
0001
0006
0002
0003
0004
 To secure better effect of
heating
When it is difficult to obtain satisfactory heating due
to installation place of the indoor unit or structure of
the room, the detection temperature of heating can be
raised. Also use a circulator or other device to circulate
heat air near the ceiling.
Follow to the basic operation procedure
1
2
3
4
5
(
• For the CODE No. in Procedure
• For the SET DATA in Procedure
DATA of shift value of detection temperature to be
set up from the following table.
SET DATA
Detection temperature shift value
0000
0001
0002
0003
0004
0005
0006
 Energy saving
Set for the energy saving operation: Energy saving
operation, Set temp. range limit, Return back and
Saving operation.
6
).
3
, specify [01].
4
, select the SET
Filter sign term
None
150 H
2500 H
(Factory default)
5000 H
1
Push the [
10000 H
"Energy saving" on the menu screen, then
push the "
2
Push the [
the item to set.
3
Push the "
Item
1. Energy
saving operation
2. Set temp.
range limit
6
).
3
, specify [06].
4
, select the SET
3. Return back
No shift
+1.8 °F (+1 °C)
+3.6 °F (+2 °C)
4. Saving operation
(Factory default)
+5.4 °F (+3 °C)
+7.2 °F (+4 °C)
+9.0 °F (+5 °C)
+10.8 °F (+6 °C)
CAUTION
Refer to the Owner's Manual supplied with the air
conditioner about "Energy saving operation", "Saving
operation".
˄ ] / [
˅ ] button to select
Set" [
F2] button.
˄ ] / [
˅ ] button to select
Set" [
F2] button.
Function
Perform the power saving
operation of the air conditioner.
Set the temperature range limit of
the remote control operation.
Set the function that changes the
temperature back to the specified
temperature automatically if the
temperature has been changed on
the remote control.
Performs operation by
suppressing excessive heating or
excessive cooling through
automatic correction of the
temperature set point.
* "No function" is displayed in
the case of a model for which
the saving operation cannot
be set.
42-EN