HDBaseT IN, 1 IR IN, 1 IR OUT and HDMI OUT. The receiver is powered directly by the Matrix Switcher. The MAX-HDBT44/P Matrix can also work with any HDBT enabled receivers. All HDMI inputs can be selected by either the front panel buttons, IR, RS 232 or GUI. The selected source is delivered to the HDBaseT outputs &...
PANEL DESCRIPTIONS Front Panel No. Name Description FIRMWARE Micro USB port for updating firmware Power Indicator OFF: No power; RED: DC power present or Standby Mode. INPUT selector Indicators Total 4 groups, and each group is set up including 4 green indicators for 4 input sources, numbered from “1”...
User Operation Guide HDBASET RECEIVER Front Panel HDBT-HD11RP No. Name Description HDMI OUT Connect to HDMI display. IR IN Plug in the IR receiver, this will receive the IR signals from the display and send through to the Matrix Switcher and then control the desired source. IR OUT Plug in the IR emitter and attached to the fornt of the display, this will send the IR signals form the Matrix Switcher to control the display which is connected to...
SYSTEM CONNECTION SYSTEM APPLICATION The new MAX-HDBT44/P 4K Matrix is designed for any installation that requires multiple sources and displays. Usage Precautions: ● The MAX-HDBT44/P 4K Matrix should be installed in a clean and dust free environment. ● Ensure that all plugs, power cords and sockets are in good condition without signs of damage.
Page 6
HDBT-HD11RP HDBaseT Receiver/s to the pre-installed cabling via additional patch leads. Plug the power supply in to the power socket on the matrix, the HDBT-HD11RP will be powered by the Matrix Switcher. Receiver HDBT-HD11RP ABtUS MAX-HDBT44/P (back view) *Specifications are subject to changes without notice.
SYSTEM OPERATIONS IR Control IR Remote Connect an IR receiver to the IR EYE port of the Matrix Switcher, users can control it through the included IR remote. Here is a brief introduction to the IR remote. 1) Standby button, press it to enter/ exit standby mode 2) INPUTS: Input channel selection buttons, range from 1~4, corresponding IR signal switched synchronously when...
Page 8
3) To convert an input to all outputs: Example: Input 1 to all Outputs → Press INPUTS 1 + ALL + ENTER By using IR & HDBaseT transmission technology, the MAX-HDBT44/P has some functions as follows: 1) Control far-end output device from local.
Page 9
See the figure below: IR Out Receiver HDBT-HD11RP ABtUS MAX-HDBT44/P (back view) Control far-end device from Local Note: The IR receiver connected to IR IN must be with IR carrier Control Local Device Remotely Connect IR receiver(s) to IR IN on far-end HDBT receiver(s), and IR Emitter(s) to IR OUT port of the switcher, and use the IR Remote of local source to control the device remotely.
Page 10
IR In Receiver HDBT-HD11RP IR Out ABtUS MAX-HDBT44/P (back view) Control local device from remote Note: Send command “%0901.” to enter infrared carrier enforcing mode if the IR Receiver connected to IR IN of the receiver is not with carrier.
RS232 communication port. This RS232 communication port is a 3-pin phoenix connector. User can use the RS232 cable (Phoenix to 9-pin D-Sub) to connect the RS232 port to PC, see as below: ABtUS MAX-HDBT44/P (back view) *Specifications are subject to changes without notice.
Page 12
User Operation Guide RS232 COMMUNICATION COMMANDS RS232 Communication Commands Note: 1) Please disconnect all the twisted pairs before sending command EDIDUpgrade[X]. 2) In above commands, “[”and “]” are symbols for easy reading and do not need to be typed in actual operation. 3) Please remember to end the commands with the ending symbols “.”...
Page 13
RS232 COMMUNICATION COMMANDS *Specifications are subject to changes without notice.
Page 14
User Operation Guide RS232 COMMUNICATION COMMANDS *Specifications are subject to changes without notice.
Page 15
RS232 COMMUNICATION COMMANDS *Specifications are subject to changes without notice.
Page 16
User Operation Guide RS232 COMMUNICATION COMMANDS *Specifications are subject to changes without notice.
Page 17
RS232 COMMUNICATION COMMANDS *Specifications are subject to changes without notice.
Page 18
User Operation Guide RS232 COMMUNICATION COMMANDS *Specifications are subject to changes without notice.
Page 19
RS232 COMMUNICATION COMMANDS TCP/IP Control Besides IR control, RS232 control, the Matrix Switcher boasts option TCP/IP port for IP control. Default settings: IP: 192.168.1.10; Subnet Mast: 255.255.255.0; Gateway: 192.168.0.1; Serial Port: 4001. IP & gateway can be changed as you need, Serial Port cannot be changed. Connect the Ethernet port of control device and TCP/IP port of the Matrix Switcher, and set same network segment for the 2 devices, users are able to control the device via web-based GUI or designed TCP/IP communication software.
Page 20
Then it’s able to control the device via GUI. GUI for TCP/IP control MAX-HDBT44/P provides with built-in GUI for convenient TCP/IP control. GUI allows users to interact with MAX-HDBT44/P through graphical icons and visual indicators. Type 192.168.1.10 in your browser, it will enter the log-in interface shown as below:...
Page 21
RS232 COMMUNICATION COMMANDS There are 2 selectable usernames – admin (default password: admin) and user (default password: user). Log in as admin can access more configuration interfaces than user. Enter username and the right password. Here is a brief introduction to the interfaces. Main: Interface shown after logging in, provide intuitive I/O connection switching.
Page 22
User Operation Guide RS232 COMMUNICATION COMMANDS Users: Display or modify credential settings, front panel lock, and GUI version If there is any modification, press Save to restore the settings, or press Cancel to withdraw. Interface: Set title bar label and button labels, press Save to save the settings *Specifications are subject to changes without notice.
Page 23
RS232 COMMUNICATION COMMANDS Configuration: Set HDCP Compliance status for every input, and manage EDID. See the screenshot below: Network: Inquire and configure network settings including MAC address, IP address, subnet mask, and Gateway Note: Logging in as user will restrict the access to the main interface only *Specifications are subject to changes without notice.
Page 24
User Operation Guide RS232 COMMUNICATION COMMANDS EDID Management MAX-HDBT44/P features EDID management to maintain compatibility between all devices. It can be controlled via EDID learning and EDID invoking. EDID learning The included IR remote can be used to enable the Matrix Switcher to learn the EDID of all sink devices.
Page 25
RS232 COMMUNICATION COMMANDS *Specifications are subject to changes without notice.
User Operation Guide TROUBLESHOOTING & MAINTENANCE If your problem persists after following the above troubleshooting steps, seek further help from authorized dealer or our technical support. *Specifications are subject to changes without notice.