Outputs: The outputs are located at the top and are numbered R1 to R6. Each output is
assigned two terminal points that correspond to the normally open contact of its associated
relay. The maximum load that can be supported by each of the relays is 5 A at 220 Vac.
When an output has been activated, the module's red LED is activated.
To facilitate the passage of the hose from the inputs and outputs of each module to the devices
to be activated, three cable glands have been placed in the boxes.
Antenna: The standard system is served with omnidirectional antennas and their respective
cables, 10 metres long, to connect to the modules. The module output consists of an SMA-type
female connector, where the 10-metre cable is connected, which is finished with an N connector
at the other end, where the antenna is connected.
Power supply: Each of the modules is delivered with a 220 Vac
the case of modules powered at 220 Vac.
Master
Slave
5-30 Vdc
5-30 Vdc
Outputs
Inputs
Outputs
Inputs
12 Vdc, 2A transformer, in
Power supply
Power supply