Fujitsu ASYG09KHCA Service Manual page 86

Hide thumbs Also See for ASYG09KHCA:
Table of Contents

Advertisement

• Limit of maximum speed based on outdoor temperature
Model name
ASYG09KHCA
ASYG12KHCA
ASYG14KHCA
1-1. Cooling operation
Outdoor
temperature drops
A zone
34°C
B zone
30°C
C zone
19°C
D zone
10°C
E zone
0°C
F zone
Outdoor
temperature
HIGH
zone
A zone
74
B zone
74
C zone
74
D zone
42
E zone
42
F zone
39
A zone
74
B zone
74
C zone
54
D zone
36
E zone
36
F zone
36
Outdoor
temperature rises
36°C
32°C
21°C
12°C
2°C
Indoor unit fan mode
MED
36
36
36
24
24
24
32
32
32
24
24
24
- (04-2) -
Unit: rps
LOW
QUIET
30
18
30
18
30
18
20
14
20
14
20
14
26
20
26
20
26
20
18
14
18
14
18
14
1. Compressor frequency control