RECEIVE CTRL MODE
May be one of four options:
1) END - TO - END In this configuration the condition asserted
locally on the control-in line (transmit) will be reflected at the
control-out line (receive) of the corresponding (far end) port.
2) LOOP BACK This loops the control lines locally within the unit.
The status of the control-in line will be reflected on the control-
out line.
NOTE: This does not loop back the DATA in/out lines.
3) SET HIGH This forces the local control-out line (receive) HIGH
(mark) regardless of any incoming line status. Allows the user
to simulate a 'break-out box' for test purposes.
4) SET LOW Same as above only with LOW (space) condition on
receive control-out line.
Unit Monitoring
DATA FRAMING (Not Adjustable)
'OK' indicates normal operation.
SHELF CLOCK (Not Adjustable)
'OK' indicates normal operation.
TEMPERATURE (Not Adjustable)
Indicates current LS DATA operating temperature.