6. CONFIGURATION

To configure the 86447 LS DATA unit , connect a PC running the supplied
Junglemux Craft Interface (JCI) software to the CI jack on the front of the unit. A
84910-05 RJ-45 cable and an 84910-06 (9 pin adapter) or 84910-07 (25 pin
adapter) or equivalent are required.
The software will display necessary programmable fields and also information
about the unit and the status of the unit. The unit will be shipped with the
programmable fields set as per the Node Assignment Drawing for the purchased
system.
The LS DATA unit does not have any hardware adjustable options. All options
for the JVT portion of the unit is shown in JCI screen Figure 5.
JCI SCREEN INFORMATION

Unit Setup

JMUX CHANNEL
Channel numbers are selectable from 1 thru 24. Each JMUX
channel occupies it's own time slot within a VT thereby making it
mandatory that no two channels be allocated the same number on
the same VT. The corresponding LS DATA unit ( at the far end
node ) must be given the same channel number.
RACK NUMBER
Identifies rack or cabinet in which the unit is located.
information will be utilized on the NMS (Network Management
System).
RACK MOUNT POSITION
Identifies location of shelf in which the unit is located for NMS.
UNIT'S SHELF SLOT
Identifies which slot position within the shelf ( 1 thru 15 ) that the
unit is located in for NMS.