Access OCR310 Product Manual page 15

Table of Contents

Advertisement

Option 9 selects between the three USB classes. CDC, Keyboard HID and Custom HID. Note that this does
not affect the serial output. However setting the Keyboard HID mode means that the setup menu is then
inaccessible over USB and will need to be changed using the serial connection.
Option A selects the behaviour when a document is determined to be unreadable. The two settings are
Ignore or output 30 asterisks. This is useful if you need confirmation that a document was swiped even if it
was not readable. The default is no output.
Option K selects the language of the keyboard used when USB class is set to Keyboard HID. The current
choices are US, UK, DK, IS, ES, DE and FR. The default is US. Other languages are available by special
request please contact Access IS Support for details.
Option S will save the changed settings and exit the setup menu. The settings will not take effect until the unit
is repowered.
Option X discards the changed settings and exits the setup menu.
All other options are reserved.
Revision 4  Access Limited 2009 - All Rights Reserved