Problem
The compressor does not
start immediately after
pressing the FROSTMAT‐
IC or after changing the
temperature.
The compressor does not
start immediately after
pressing the COOLMATIC
or after changing the tem‐
perature.
Water flows inside the re‐
frigerator.
Water flows on the floor.
Temperature cannot be
set.
DEMO appears on the
display.
The temperature in the
appliance is too low/too
high.
Possible cause
This is normal, no error
has occurred.
This is normal, no error
has occurred.
The water outlet is clog‐
ged.
Food products prevent
water from flowing into
the water collector.
The melting water outlet
is not connected to the
evaporative tray above
the compressor.
The FROSTMATIC or
COOLMATIC function is
switched on.
The appliance is in dem‐
onstration mode.
The temperature regulator
is not set correctly.
The food products tem‐
perature is too high.
Many food products were
stored at the same time.
The FROSTMATIC func‐
tion is switched on.
The COOLMATIC func‐
tion is switched on.
Solution
The compressor starts after
some time.
The compressor starts after
some time.
Clean the water outlet.
Make sure that food prod‐
ucts do not touch the rear
plate.
Attach the melting water out‐
let to the evaporative tray.
Switch off FROSTMATIC or
COOLMATIC manually, or
wait until the function resets
automatically to set the tem‐
perature. Refer to "FROST‐
MATIC or COOLMATIC
function".
Keep the OK pressed for ap‐
proximately 10 seconds until
a long sound is heard and
display shuts off for a short
time.
Set a higher/lower tempera‐
ture.
Let the food products tem‐
perature decrease to room
temperature before storage.
Store less food products at
the same time.
Refer to "FROSTMATIC
function".
Refer to "COOLMATIC func‐
tion".