Clevertest and Clevertest Plus
Refer to the supplementary operation guide supplied with the Product.
After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red
flashing for a period up to 2 minutes.
Zoneworks and DATA Monitored Options
LP battens with part numbers –ZW
and -DATA
(nodes). These fittings are monitored using either Powerline Carrier Technology that utilising the power
cable to provide data communication or a dedicated data cable to/from data routers installed on a
dedicated data trunk connected to a central Server (can also be connected via Ethernet/Internet/Fibre).
Zoneworks software on the server is used to monitor, coordinate testing and collate test data from each
batten. Zoneworks Battens can be commissioned by a single push of the test switch or scanning of the
supplied barcode. The LED Test Switch indicator provides a multifunction indication of the status of the
Fittings during testing and normal operation:
State
LED Operation
Commissioned
LED on Solid (Green)
Un-commissioned
LED flashes at 0.5Hz (0.5s Green, 0.5s Yellow)
Emergency Light Test In Progress
LED flashes at 3s On (Yellow) & 0.5s Off
In the case of the DATA version a 2-way "figure 8" cable and terminal block facilitates the connection to
the DATA network via a multi-drop bus (daisy chain connection). For further information of installation of
a Zoneworks LW system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl.
DATA version)
DALI EM Option
LP battens with part numbers
-DALI
are fitted with DALI modules (nodes) that facilitate connection and
rd
integration to 3
Party Lighting Control Systems. Before installing the -DALI batten, please confirm that
the Lighting Control System has the capability to monitor DALI Emergency Luminaires. The batten will
be addressed and configured into the control system by the Lighting Control System Commissioning
Technicians and not Clevertronics.
State
LED Operation
Commissioned/ Un-commissioned
LED on Solid (Green)
Emergency Light Test in progress
LED flashes at 1s On (Yellow) & 1s Off
"IDENTIFY COMMAND"
Fitting goes into emergency mode for 10 seconds
A 2-way "figure 8" cable and terminal block facilitates the connection to the DALI network OR a 5/6way
"structured wiring system" lead and plug facilitating the power and DALI connection. DALI connections
are marked as Da Da.
are fitted with Zoneworks communications modules
LP™ Sustained Emergency LED Battens
Installation & Maintenance Instruction Leaflet
Designed in Australia to comply with the
requirements of AS2293.3: 2005 and AS/NZS
CISPR15: 2011.
NOTE: Standard product codes with this symbol
enabled with Clevertest Plus capability. Please refer to
the operation guide supplied with the product for details.
Models:
CBS2LEDS-DIF-yy-zz
Testing:
Manual Test
yy = Blank
Zoneworks
yy = ZW
Zoneworks DATA
yy = DATA
DALI Compatible
yy = DALI
Clevertest
yy = CT (NOTE: Products supplied with the Clevertest Plus Symbol
activated with Clevertest PLUS capability. Please refer to the operation guide
supplied with the product for details).
Spare Parts:
1550050
BATT: LP 3.2V 3200mAh 70mm lead,no BRKT.
1100634
LP, Emergency LED PCA
CLIFE-CKIT-NP
Lifelight, Control Only, LP
8002695
PCA: LED Strip 8S6P, ALS-13-840-0-02
1330029
LED Driver - 40W, 500-1050mA, 15-50V
1330038
LED DALI Driver - 25W, 350-1050mA, 20-50V (-DD Option)
1190117
SENSOR:Microwave Motion, IP20, MC602S
Important:
It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before installation,
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in
accordance with the relevant Australian and International Standards.
Victoria (Head Office & Manufacturing)
195 Chesterville Rd Moorabbin VIC 3189
Phone: +61 3 9559 2700
Fax: +61 3 9559 2799
News South Wales
Phone: +61 2 8805 6400
Fax:
+61 2 8805 6444
Queensland
Phone: +61 7 3442 9700
Fax:
+61 7 3442 9777
South Australia/Northern Territory
Phone: +61 8 8301 8800
Fax: +61 8 8351 8286
are
Western Australia
Phone: +61 8 9248 3720
Fax: +61 8 9248 3725
New Zealand
Phone: +64 800 548 448
Options:
On/Off Sensor Control
zz=MS
DALI Driver
zz=DD
1948769
V1.1
are
July 2019
Need help?
Do you have a question about the LP CBS2LEDS-DIF Series and is the answer not in the manual?
Questions and answers