FCOT info -
Trunk Info -
In the above examples, the highligthed rxbuffsize is 2112 bytes. This represents the default settings on
a Cisco MDS 9000 switch interface.

Troubleshooting a ZONE Merge Failures

In the example below the show interface command indicates that the E port did not come up due to a
zone merge failure. (Zoning information is on a per VSAN basis. Therefore, for a TE port, it may be
necessary to verify that the zoning information does not conflict for any allowed VSAN.)
switch# show interface fc2/14
fc2/14 is down (Isolation due to zone merge failure)
A E port will segment with (isolation due to zone merge failure) if the following are true.
To verify the zoning information use the following commands:
switch# show zone vsan 1
switch# show zoneset vsan 1
Two different approaches may be followed to solve a zone merge failure:
OL-5183-02, Cisco MDS SAN-OS Release 1.3
Min Speed: 1000
Max Speed: 2000
Module Type: 8
Connector Type: 7
Gigabit Eth Compliance Codes: 0
FC Transmitter Type: 3
Vendor Name: PICOLIGHT
Vendor ID: 0:4:133
Vendor Part Num: PL-XPL-00-S23-28
Vendor Revision Level:
trunk vsans (allowed active) (1)
Hardware is Fibre Channel, WWN is 20:4e:00:05:30:00:63:9e
vsan is 1
Beacon is turned off
40 frames input, 1056 bytes, 0 discards
0 runts, 0 jabber, 0 too long, 0 too short
0 input errors, 0 CRC, 3 invalid transmission words
0 address id, 0 delimiter
0 EOF abort, 0 fragmented, 0 unknown class
79 frames output, 1234 bytes, 16777216 discards
Received 23 OLS, 14 LRR, 13 NOS, 39 loop inits
Transmitted 50 OLS, 16 LRR, 21 NOS, 25 loop inits
If the active zonesets on the two switches differ from each other in terms of zone membership
(provided there are zones at either side with identical names )
If the active zoneset on both switches contain a zone with the same name but with different zone
members
.Overwrite the zoning configuration of one switch with the other switch's configuration. This can
be done with the following commands:
switch# zone copy interface fc2/7 import vsan 1
switch# zone copy interface fc2/7 export vsan 1