Content
Product overview ................................................. 2
Scope of Supply ................................................ 2
Standard Components ..................................... 2
Overview ........................................................... 3
Product informations ........................................... 4
Intended Use .................................................... 4
Product Description ......................................... 4
Areas of Application ........................................ 4
Dimensions ....................................................... 5
Technical Data .................................................. 5
Identification Label .......................................... 5
Preconditions ........................................................ 6
Expert Knowledge ........................................... 6
Site of Installation ........................................... 6
Installation Situation ....................................... 6
Operating Mode ................................................... 7
Convection Principle ........................................ 7
Symbol key
Warning: Danger of electrical voltage
Warning: Danger zone
Warning: Hot surface
Installation ............................................................ 8
Installation Preparation ................................... 8
Height Adjustment ........................................ 8
Free/Full load Capacity ..................................... 8
Installation Preparation ................................... 9
Protection Cover .............................................. 9
System Extensions ............................................ 10
Electrical Connection ....................................... 10
Circuit Plan ....................................................... 11
Internal Wiring ................................................. 12
Detailed Connection Plan ................................ 12
Connection Plan ............................................... 13
Designer Grille Roll .......................................... 14
Start-up ................................................................. 15
Preparation for Start-up .................................. 15
Operation/Use .................................................. 15
Maintenance ........................................................ 16
Maintenance/Cleaning ..................................... 16
Declaration of Conformity .............................. 17
Manual Storage ................................................ 17
Technical Support ............................................. 17
Copyright .......................................................... 17
Warning: Hand injuries
Useful hint/advice
8-D24-53-031.12
ESK 180 -110

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESK 180-110 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mohlenhoff ESK 180-110

  • Page 1: Table Of Contents

    MANUAL Electric System Convector Content ESK 180-110 Product overview ..........2 Installation ............8 Scope of Supply ..........2 Installation Preparation ........8 Standard Components ........2 Height Adjustment ........8 Component for Night Setback Control ... 2 Free/Full load Capacity ........8 Overview ............
  • Page 2: Product Overview

    Alpha Thermostat Standard AR 2010 S2-S, 230 V, 50/60 Hz Digital room temperature thermostat for controlling Alpha-Actuators depending on target and actual tempe- Electric System Convector rature. ESK 180-110 Alpha Thermostat Comfort HANDBUCH Elektro-Systemkonvektor Heizen Inhalt ESK 180-110 Produktübersicht ........2 Montage .............
  • Page 3: Overview

    Product Overview Overview Endplate Control box ELS 1000 System trough Air channeling bar System bulkhead Electrical heating rod Temperature switch and safety fuse Heat exchanger Height Adjustment Blocks 8-D24-53-031.12 ESK 180-110...
  • Page 4: Product Informations

    Product Informations Intended Use Areas of Application Möhlenhoff Electric System Convectors are exclusively intended for heating The Electric System Convector ESK is used when the architectural situation in closed rooms for covering remaining heat demands, or for the full hea- requires an economical and comfortable room heating system.
  • Page 5: Dimensions

    Product Informations Dimensions Identification Label window side Fensterseite - Window side Typ: ESK 180-110-1250 ID.-Nr.: ___________________ Auftrag: Pos.: 1-B92-24-200 Bestell Nr.: 0726 The convector lengths KL follow from the combination of heat ex- changer that are 500 mm, 1000 mm, and 1250 mm with connection space on both ends of 250 mm each.
  • Page 6: Preconditions

    Preconditions Expert Knowledge Installation Situation These instructions require special knowledge corresponding to an officially acknowledged degree in one of the following professions: - Electrical Equipment Installer or Electronics Engineer - Systems mechanic for sanitary, heating and air condition technology according to the profession designations officially announced in the Fe- deral Republic of Germany, as well as according to comparable professions within the European Community Law.
  • Page 7: Operating Mode

    Convection Principle – Natural Convection (Heating) 1. cooled air (cold air gradient) 2. warmed air for cold air barrier and room heating 8-D24-53-031.12 ESK 180-110...
  • Page 8: Installation

    Installation Installation Preparation Free/Full load Capacity 1. Carefully remove the ESK from the packaging. 2. Remove the protective covering of the convector trough. 3. Under the protection cover (marked with a point) you will find the A = 500 mm required accessories for connection.
  • Page 9: Installation Preparation

    The electric connection side is marked „ “ on the protective cover. Interior adjustment block: Screw in the threaded bolts Interior adjustment block: Height adjustment Levelling Outer adjustment block: Latch into the trough profile Outer adjustment block: Fix with screws 8-D24-53-031.12 ESK 180-110...
  • Page 10: System Extensions

    Installation System Extensions Electrical Connection System Connectors (option) Note for electrical connection there are 3 heating element types: • 220 W 500 mm length • 470 W 1000 mm length • 570 W 1250 mm length All ESK are equipped with the ELS 1000 for the electrical connection. Through this controller, the resistance and control current are, in relation to the connection conditions and power, virtually independent.
  • Page 11: Circuit Plan

    Installation Circuit Plan All connection and circuit diagrams are given without electrical protection devices/measures! AR 2010 S2-S AR 2010 K2-S AR 2010 C2-S DS 1000 AS 1000 Optional controller for temperature setback without an Alpha-Thermostat Control 8-D24-53-031.12 ESK 180-110...
  • Page 12: Internal Wiring

    Installation Internal Wiring HP 2 HP 3 HP 1 ELS 1000 Connecting box 1 Detailed Connection Plan ELS 1000 Connecting box 1 Heating cartridge HP 2 6,3 AT Thermostatic switch 2 Thermostatic switch 3 6,3 AT Heating cartridge HP 3 Alpha Thermostat Comfort 230V AC Thermostatic switch 1...
  • Page 13: Connection Plan

    Alpha Thermostat Control, e. g. DS 1000 inadmissible! We therefore recommend cor- Alpha Thermostat 230 V AC responding terminals to be provided by the with Mounting Base AS 1000 customer. 8-D24-53-031.12 ESK 180-110...
  • Page 14: Designer Grille Roll

    Installation Designer Grille Roll Designer grille roll protector Danger of jamming! Always fix the designer grille roll protector above the convector fan. It serves as a protection against reaching into the fan. Fit the designer grille roll into the convector trough in a way that a space of the size of a grille rod is over the recess in the side parts of the convector.
  • Page 15: Start-Up

    Operation/Use Switch on the electric circuit for the power supply of the ESK. For AR 20xx-x-S, the desired temperature can be set. Further information can be found in the user manual of the Alpha-Thermostat. 8-D24-53-031.12 ESK 180-110...
  • Page 16: Maintenance

    Maintenance Maintenance/Cleaning The following procedures (1 –3) can be performed by the end user: Execution: see Cleaning intervals maintenance and 1. Clean the Designer Grille in months cleaning instructions Dry: Cover Grille see point 1 Vacuum the Designer Grille at regular cleaning in- Ventilation duct see point 2 tervals during normal cleaning.
  • Page 17: Declaration Of Conformity