Maintenance And Storage - Lanaform Moony Manual

Humidifier 3 in 1
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Remove the reservoir lid by its handle
(Fig. 3, point 1).
Fill the reservoir with clean distilled or
demineralised water up to a maximum
40°C (Fig. 3, point 2). For best humidifi-
cation and product lifetime, make sure
that the water level is still between the
minimum and maximum levels shown in
the reservoir (Fig. 1-2).
Replace the cover (Fig. 3, point 3).
report_p PLEASE NOTE
DO NOT fill the reservoir above the indi-
cator showing MAX filling level.
DO NOT pour the water into the base
through the exhaust vent (Fig. 2, point 14).
DO NOT pour essential oils on to the pro-
jection lens (Fig. 2, point 17).
Air humidification function
With dry hands, insert the end of the
adapter in the DC jack socket located on
the back of the diffuser (Fig. 1, point 3).
The humidifier is fitted with 3 mist in-
tensities:
Press the humidification button (Fig. 1,
·
point 6) once: the light is green and hu-
midification has been activated at the
lowest intensity (120 ml/hr);
·
Press the humidification button twice: the
light is blue and humidification has been
activated at medium intensity (150 ml/hr);
·
Press the humidification button three
times: the light is red and humidification
has been activated at the highest inten-
sity (180 ml/hr);
·
Press the humidification button four
times: the light goes out and humidifi-
cation stops.
·
When the reservoir is empty, the light flashes
red (x10) and humidification stops automa-
tically. The other functions remain active.
Use of essential oils
To diffuse organic essential oils in the room,
pour a few drops of organic essential oils
(maximum 3-4) directly into the water and
then put the lid back on the reservoir (Fig.
3, point 3).
report_p WARNING
ADDITIONAL INFORMATION RELATING TO
THE USE OF ESSENTIAL OILS
Before using essential oils, please check
the harmful effects that use of these prod-
ucts may have on your health.
Always choose quality essential oils that
are pure, 100% natural and intended for
diffusion. Use them in moderation and
with care. Follow the instructions and
warnings stated on the packaging of the
essential oils, in particular noting that:
Pregnant women, people with epilepsy,
·
asthmatics and people who suffer from
allergies, those with heart problems
or serious illnesses should not use es-
sential oils.
·
Essential oils should be used only for
periods not exceeding 10 minutes in
the room of a baby (under 3 years old)
and only when the baby is not actually
in the room.
Make sure that children and minors do
not play with or use the device.
Just a few drops (3 to 4 drops at most) of
essential oils are sufficient to ensure that
the device works properly and the scent
is diffused. Excessive use of essential oils
could damage the device.
Lanaform cannot be held liable in the
event of accidental damage resulting from
any use contrary to the instructions given
in this manual.
Nightlight function
Press the nightlight button (Fig. 1, point
12) once: the light switches on and the
nightlight mode is active;
Press the nightlight button twice: the light
switches off and the nightlight mode is
disabled.
Light projection function
Press the projection button (Fig. 1, point
5) once: the light is blue and the active
light projection active for a period of 20
minutes;
Press the projection button twice: the
light is green and the light projection is
active continuously;
Press the projection button three times:
the light goes out and the light projection
is disabled.
report_p PLEASE NOTE: EVEN THOUGH
THERE IS A SAFETY DEVICE THAT
STOPS THE TRANSDUCER FROM
WORKING, DO NOT LEAVE THE DE-
VICE CONNECTED WHEN YOU ARE
NOT USING IT.

MAINTENANCE AND STORAGE

Always switch off the humidifier and empty
the water in the reservoir before cleaning
or storing it.
EN
FR NL DE PL CS SL HR BG SV LT
If the water is hard, i.e. if it contains too much
calcium and magnesium, it may leave a "white
powder" in the device and cause frothing on
the surface of the basin, on the transducer
(ceramic pellets producing ultrasound) and
on the internal walls of the water reservoir.
Frothing on the surface of the transducer
means that the device will not work properly.
We recommend:
1 Using water that has been boiled
and cooled or distilled water
each time the device is used,
2 Cleaning the reservoir every 3 days and
cleaning the transducer every week,
3 Changing the water in the reservoir
regularly so that it stays fresh, and not
leaving it there for longer than 2 days,
4 Cleaning the entire device and
making sure that all its parts are
completely dry when it is not in use.
To clean the transducer:
1 Turn the mist conductor (Fig. 1,
point 9) anti-clockwise until the
release markings are aligned,
then remove the conductor
2 Place 2 to 5 drops of vinegar on its
surface and leave for 2 to 5 minutes.
3 Brush the foam off the surface
with a soft brush. Do not use a
hard tool to scrape the surface.
4 Rinse the transducer with clean water.
5 Do not use soap or other basic
substances to clean the transducer.
To clean the basin:
1 Clean the basin with water using a soft
cloth and vinegar if there are foam
OR limescale deposits on the inside.
2 If the foam covers the safety
switch, put a few drops of vinegar
on it and clean it with a brush.
3 Rinse the basin in clean water.
STORAGE:
1 Clean and dry the humidifier care-
fully using ultrasound, following
the maintenance instructions.
2 Let it dry completely before
storing it. Do not store it if there
is still water in the base.
3 Store the device in a dry, cool place
out of the reach of children.
5
/ 36 ENGLISH

Advertisement

Table of Contents
loading

Table of Contents