SERVICES

This menu makes it possible to manage some auxiliary services. From the MAIN MENU:
Select DATA & CONFIGURATION. The following screen is displayed:
Select SERVICES and press ENTER.
NOTE: The SERVICES MENU is only available to authorised technicians

REFRIGERANT MANAGEMENT

The machine keeps track of the operations done on refrigerant fluid: recovery, system refilling,
inner bottle filling. For any operation, a record is made with date, time, type of operation,
quantities involved, operator nr., inner bottle refrigerant fluid availability. The machine can keep
up to 100 records. From the 90th operation on, a message appears indicating how many
operations can be done..
From the SERVICES MENU:
Select REFRIGERANT MANAGEMENT and the following screen is displayed:
Select DELETE and press ENTER to delete all the records from the memory.
Select PRINT and press ENTER to print the last 25 operations in the memory.
NOTE: If the machine is connected to a personal computer by means of a USB cable, the
GESTREF.TXT file can be downloaded that contains all the operations in the memory.

PASSWORD

From the SERVICES MENU:
Select PASSWORD and the following screen is displayed:
INSTRUCTIONS MANUAL
AUTOMATIC PROCEDURE
ASSISTED PROCEDURE
<DATA & CONFIGURATION>
MAINTENANCE xx.xkg
DATA
CONFIGURATION
<SERVICES>
REFRIGERANT MANAGEMENT
PASSWORD
COUNTERS
REFRIGERATION MANAGEMENT
DELETE
PRINT
REFRIGERATION MANAGEMENT
PASSWORD
COUNTERS