New Oil Reintegration; Tracer Reintegration; Charging The A/C System - Wow WAC 2200 Instruction Manual

Air conditioning service unit
Hide thumbs Also See for WAC 2200:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

NEW OIL REINTEGRATION

This operation can be carried out ONLY following a vacuum operation and before charging.
Select the assisted procedure by pressing ENTER when the "ASSISTED PROCEDURE"
message flashes on the LCD.
The following message will be displayed:
Press ENTER to continue.
Select the OIL by pressing ENTER when "OIL XX CC" flashes on the LCD. Set the volume of
new oil to be reintegrated, in cc. Press ENTER to confirm. Open the high- and low-pressure
taps (if the A/C system is equipped with a single quick-connect coupling for high or low
pressure, open only the relative tap) of the machine and press START.

TRACER REINTEGRATION

This operation can be carried out only following a vacuum procedure and before charging.
Select the assisted procedure when the "ASSISTED PROCEDURE" message flashes on the
LCD, and press ENTER. Select "TRACER" and set the volume of tracer to be reintegrated, in
cc. Press ENTER to confirm.
The following message will be displayed:
Press ENTER to continue.
Open the high- and low-pressure taps (in the case of an A/C system with only one pressure
coupling—high or low—open only the relative tap) on the machine and press START.
NOTE: To enable the TOP UP TRACER function, use the OPTIONS MENU.

CHARGING THE A/C SYSTEM

Select the ASSISTED PROCEDURE by pressing ENTER when the "Assisted Procedure"
message flashes on the LCD. Select charging by pressing ENTER when "CHARGING XXXX
G" flashes on the LCD. The following screen is displayed:
1) Use keys 0 to 9 to enter the quantity (in grams) of refrigerant to be charged into
the A/C system and press ENTER.
NOTE: For most systems the quantity of fluid to be refilled is indicated on a plate
INSTRUCTIONS MANUAL
ATTENTION
USING PAG OIL OR TRACER IN
HYBRID VEHICLES MAY DAMAGE
THE COMPRESSOR.
USE ONLY SUITABLE OIL WITH A
SEPARATE DEVICE.
ATTENTION
USING PAG OIL OR TRACER IN
HYBRID VEHICLES MAY DAMAGE
THE COMPRESSOR.
USE ONLY SUITABLE OIL WITH A
SEPARATE DEVICE.
ASSISTED PROCEDURE
CHARGING
<xxxg>
DATABASE
pag.22 - 12/11/2015

Advertisement

Table of Contents
loading