Subsequently perform another cleaning cycle and check the setting. Correct the setting if necessary.
Check the setting again when the desired water quality has been reached.
6.

Operation

6.1

Control system overview

1
Display
for displaying the operating status
for displaying the menus and values for setting the drum filter
the current water temperature [°C] is displayed as standard
2
On|Off button, Quit Error
for switching the drum filter on or off
for resetting error messages
3
LED, 2 colours
LED is lit red: Control system switched OFF (OFF)
LED is lit green: Control system switched ON (ON)
4
Menu button
For selecting the following menus and changing the values:
cleaning time "Cleaning" (CL)
extended cleaning time "Extra Cleaning" (EC)
time-dependent cleaning "Interval" (In)
5
Clean button
for starting the manual cleaning cycle and for cancelling the active cleaning cycle
LED (6) is lit when the cleaning cycle is active
6
Blue LED
LED is lit: Cleaning cycle active
6.2

Switching ON/OFF

How to proceed
Switching on:
On|Off
Press
for 3 s.
LED (3) is lit green.
The display indicates On for approx 5 s.
Switching off:
On|Off
Press
for 3 s.
LED (3) is lit red.
The display indicates OFF.
52
Information
The display indicates the water temperature as standard.
If there is a voltage interruption, the control system will remain switched
on.
The control system switches off all functions.
If there is a voltage interruption, the control system will remain switched
off.