Summary of Contents for TREND AIRSHIELD PRO

  • Page 1 AIRSHIELD RESPIRATOR APPROVED TO EN12941:1999 VISOR APPROVED TO EN166:2002 Please read these instructions before use.
  • Page 2: Table Of Contents

    28 days of purchase. splash. CONTENTS The Airshield Pro is powered by a rechargeable battery pack held inside the respirator. Air INTRODUCTION ______________________ 1 is filtered through the respirator to provide a SUITABILITY FOR USE ________________ 2 constant flow of clean air over the face.
  • Page 3: Suitability For Use

    AIR/PRO SUITABILITY FOR USE Suitable for use under COSHH, CAW, CLAW and This respirator must be used strictly in IRR. accordance with these instructions. Do not Head Protection: This is NOT an industrial use this respirator for protection against safety helmet. unknown atmospheric contaminants or when concentrations of contaminants are unknown or immediately dangerous to life or health, or in...
  • Page 4: Approvals

    AIR/PRO APPROVALS TECHNICAL DATA EUROPE Type: Respirator, powered particle This product has been shown to meet the filtering device. requirements of Article 10 of the European Voltage: Directive 89/686/EEC and is manufactured in Head size 54 to 61cm accordance with Article 11B quality monitoring system, and thus is CE marked.
  • Page 5: Safety

    AIR/PRO SAFETY 5. Consider working environment. Do Keep cord from heat, oil and sharp edges. Always trail the power cord not use the product in the rain or in WARNING: away from the work area. a damp environment. Keep work area well lit.
  • Page 6 Recommended speeds ensure there is sufficient clearance spanner or key and to the torque are shown in the Trend Routing between cutter tip and inside edge value provided by the manufacturer. Catalogue and/or website.
  • Page 7: Electrical Safety

    AIR/PRO ELECTRICAL SAFETY To reduce risk of damage to the charger, pull by charger body rather than cord when Power Supply disconnecting charger from power supply. The charger has been designed for one voltage Make sure cord is located so that it will not only.
  • Page 8 Charge the battery packs only in a Trend AIR/ Never attempt to open the battery PRO charger. pack for any reason. If the plastic...
  • Page 9: Additional Precautions

    AIR/PRO ADDITIONAL SAFETY ITEMS ENCLOSED PRECAUTIONS FOR 1 x Airshield Pro complete AIR/PRO 1 x Airflow indicator Control Of Substances Hazardous to Health 1 x Pair TH2P filters (COSHH) recommend that Respiratory 1 x 8 Hour rechargeable battery Protective Equipment should be stored in a cool dry place.
  • Page 10: Description Of Parts

    AIR/PRO DESCRIPTION OF PARTS A. Cover B. TH2P Filter C. Battery pack D. Head cover & face seal E. Switch and contact assembly F. Motor G. Visor lock knob H. Head band assembly I. Brow comfort pad J. Visor K. Visor overlay L.
  • Page 11: Assembly, Adjustment & Operation

    AIR/PRO Battery Pack Charging ASSEMBLY, ADJUSTMENT & OPERATION Fit the battery charger connector into the rear of the electronics unit and connect the charger to a mains AC supply. The LED lights Battery Pack Installation up and remains lit even after a full charge has been completed.
  • Page 12: Visual Inspection

    AIR/PRO Visual Inspection Check the face seal material for damage. Hold plastic neck of air filter to fit and Check the face seal attachment to the remove. Do not pull on filter. respirator chassis and visor. To correctly use the airflow indicator, the Check the visor seal for damage.
  • Page 13: Fitting Procedure

    AIR/PRO Ensure that the face seal around the chin and Fitting Procedure sides is pulled away from the frame and visor The crown strap has a soft pad that needs to and not towards it. be removed before adjustment. Adjust the Check the fit of the face seal in a mirror crown strap length on the headband so that and/or run a finger around the line of the face...
  • Page 14: Accessories

    AIR/PRO ACCESSORIES Do not immerse the respirator in water or any other fluids. Please use only Trend original accessories. Do not use organic solvents or abusive Ref. AIR/P/1 TH2P filter pack (pair) cleaning agents on any part of the equipment.
  • Page 15: Routine Checks

    AIR/PRO Routine Checks Storage The expected life of the visor is approximately 3 The respirator should be placed in the carry years if well maintained and cleaned. (Care must bag, stored within a temperature range of 5°C be taken not to scratch the visor). to 40°C and out of direct sunlight.
  • Page 16: Replacement Spare Parts

    Replacement parts and accessories supplied by Trend should only be used. The use of accessories not supplied by Trend will not be guaranteed and invalidate such National approvals as held by Trend. Modifications to the respirator will make the approvals invalid and the use illegal under National Laws and Guidance.
  • Page 17: Air Filter

    AIR/PRO Air Filter Face Seal To replace air filter, lift the cover as shown. Replace the face seal as shown. Starting from the centre of the visor, pop up studs on face seal. Release from front of helmet. Hold the neck of the fitted air filter and push firmly towards sealing face to release from securing tabs and lift filter upwards to remove.
  • Page 18: Headband

    AIR/PRO Visor Headband Remove face seal and visor as shown. Remove the seven face seal pop studs from visor. Replace the old or damaged visor assembly Install a new headband assembly as shown. as shown. Release nuts and screw and remove the headband from the helmet.
  • Page 19: Fan Motor Unit

    AIR/PRO Electronics Unit / Switch Housing Fan-Motor Unit Lift the cover and replace the electronics unit as Lift the cover. Replace fan/motor assembly as shown below. shown below: Disconnect fan/motor electrical lead from the electronics unit. Remove the two screws securing the front air duct.
  • Page 20: Environmental Protection

    Please call Trend Customer Services for advice as to how to dispose of unwanted Trend electrical products in an environmentally safe way or visit www.trend-uk.com Business User Please call Trend Customer Services for disposal of unwanted Trend electrical products.
  • Page 21: Spare Parts

    AIR/PRO Please use only Trend original spare parts. AIR/PRO - SPARE PARTS LIST V4.0 10/2016 Desc. Ref. Fan/Motor WP-AIR/P/01 Airflow Indicator WP-AIR/P/02 Head Cover & Face Seal WP-AIR/P/03 Switch & Contact Assembly WP-AIR/P/05 Carry Bag WP-AIR/P/06 Visor WP-AIR/P/07 Cover WP-AIR/P/08...
  • Page 22 AIR/PRO AIR/PRO - SPARE PARTS LIST V4.0 10/2016 -IB-...
  • Page 23 RECYCLABLE © Copyright Trend 2015, 2016, 2017. No part of this publication may be reproduced, stored or transmitted in any form without prior permission. Our policy of continuous improvement means that specifications may change without notice. Trend Machinery and Cutting Tools cannot be held liable for any material rendered unusable or any form of consequential loss.