Download Print this page
North T10 Use And Maintenance Instructions

North T10 Use And Maintenance Instructions

Gas water grill

Advertisement

Quick Links

GAS WATER GRILL
MODELS
Τ10 • Τ20 • T30
USE AND MAINTENANCE INSTRUCTIONS
0051 -
SOTIRIOS D. PRODANAS & C.O.
PROFESSIONAL ELECTRIC & GAS EQUIPMENT FOR RESTAURANTS – PATISSERIES – SNACK BARS
NATIONAL ROAD KILKIS – THESSALONIKI. P.C.:61100 GALLIKOS KILKIS CROSSROADS – P.O. BOX: 40070. P.C 56404
TEL : + 30 23410
41991, 41819, - FAX:
+ 30 23410
41539 - email: info@north.gr – Http: //www.north.gr
Carefully read the manual before
installing and operating this gas heated water grill
1

Advertisement

loading

Summary of Contents for North T10

  • Page 1 NATIONAL ROAD KILKIS – THESSALONIKI. P.C.:61100 GALLIKOS KILKIS CROSSROADS – P.O. BOX: 40070. P.C 56404 TEL : + 30 23410 41991, 41819, - FAX: + 30 23410 41539 - email: info@north.gr – Http: //www.north.gr Carefully read the manual before installing and operating this gas heated water grill...
  • Page 2 INDEX GENERAL INFORMATION Page 03 Standards and requirements TECHNICAL FEATURES Page 04 Data table and general description of the gas water grill Technical data plates INSTALLATION (only for the installer) Page 05 Installation in premises Packing Positioning Gas connection to the network Gas pressure and nominal heat input controls Adaptation to a different gas 3.6.1 Replacing the main nozzle and adjusting its primary air...
  • Page 3: General Information

    Please remember that any alteration of parts of the grill could lead to accidents. For this reason, the producer NORTH declines any responsibility for any injury to persons or damage to things as a result of improper and forbidden actions.
  • Page 4: Technical Features

    TECHNICAL FEATURES Data table and general description of the gas water grill This water grill is made of a stainless steel frame, a cooking grid and radiant elements under which the flames of main burners heat up the cooking area. Each cooking unit is heated by an atmospheric burner with eight flames elements controlled by a gas tap.
  • Page 5 INSTALLATION (only for the installer) Installation in premises The installation and the first starting on must be done by qualified personnel, authorised by the manufacturer. Appliances must be installed in accordance with the national safety standards regarding gas heated appliances. This gas heated water grill must be installed in a well-ventilated place having permanent ventilation ducts to guarantee a sufficient exchange of comburent air and to keep the work premise healthy.
  • Page 6 Positioning Make sure there is enough space available to place the appliance and that the surface it stands on is stable and level. Make sure the appliance is level on the surface available. If necessary, regulate its height accordingly, by adjusting the legs of the appliance.
  • Page 7 Nominal heat input of appliance can be measured using the gas meter instrument of the premise and a chronometer; you have to measure the exact gas flow per unit of time, which is consumed when the water grill (being the only gas heating appliance on) is working at maximum power. This measurement should be compared to the gas consumption data in technical table A.
  • Page 8 3.6.2 Replacing the pilot nozzle and adjusting its primary air For each pilot burner, consult technical data on table 3, see Fig. 5 and proceed as follows Access to the pilot burner after removing the cooking grids, the radiant elements, the drawers •...
  • Page 9 WARNING! After an adaptation to a different gas please remember to: Apply an indelible sticker on the technical data plate with the data of the new installation. • Fix the new seals on the regulated parts (primary air bushes, nozzles and by-pass screws). •...
  • Page 10 INSTRUCTIONS FOR USING THE WATER GRILL (for the user) Preliminary warnings before operating the appliance Before operating the appliance, verify it is in efficient condition and it's been installed in an suitable • premise with a well maintained ventilation system capable to keep the work area healthy. Check the electrical hood is in perfect working order and make sure that the volume of air required for combustion isn't obstructed in any way by objects around or under the grill.
  • Page 11 • The gate valve must be checked at least once a year and, if necessary, restored the protection of specific oil. • If such an accurate observance of the contained instructions in this manual are observed, NORTH appliances will allow perfect use and performances for a long time.