North DKE6 Technical Instruction Manual

North DKE6 Technical Instruction Manual

Electric gyros

Advertisement

Technical instruction
manual for use and maintenance
ELECTRIC GYROS
MODEL
DKE6 – DKE8 –MKDKE6- MKDKE8
These appliances comply with requirements of E.E.C 73/23/CEE EN 60335-1:02 EN 60335 - 2 – 48:03
SOTIRIOS D. PRODANAS
PROFESSIONAL ELECTRIC & GAS MACHINES FOR RESTAURANTS - PATISSERIES - SNACK BAR
OFFICE - FACTORY : 14km National road Thessaloniki - Serron (Liti) P.C. 545 00 – TEL. & FAX: ++30 3940 72770-73185-73184
P.O BOX 400 70, P.C : 560 00
www.north.gr
- e-mail :
northgas@spark.net.gr

Advertisement

Table of Contents
loading

Summary of Contents for North DKE6

  • Page 1 ELECTRIC GYROS MODEL DKE6 – DKE8 –MKDKE6- MKDKE8 These appliances comply with requirements of E.E.C 73/23/CEE EN 60335-1:02 EN 60335 - 2 – 48:03 SOTIRIOS D. PRODANAS PROFESSIONAL ELECTRIC & GAS MACHINES FOR RESTAURANTS - PATISSERIES - SNACK BAR OFFICE - FACTORY : 14km National road Thessaloniki - Serron (Liti) P.C.
  • Page 2: Specifications

    Electrical Supply MKDKE6 230V AC / 400V 3N AC 50Hz MKDKE8 230V AC / 400V 3N AC 50Hz DKE6- DKE8 230V AC / 400V 3N AC 50Hz IP Grating ΙP 20 Appliance’s Safety Complies to ΕΝ 60335-1 and 60335-2-42 requirements.
  • Page 3 • AISI 304 stainless steel spit. • AISI 430 stainless steel scoop. Electrical Components • Infrared Heating Elements DKE6-MKDKE6: 6 x 700 Watt. DKE8-MKDKE8: 8 x 700 Watt. • Spit’s motor 12 Watt. • Fire resistan wiring. • Terminals’ fasteners.
  • Page 4: General Information

    ⇒ This technical manual includes instructions for the installation, operation, care and maintenance of gyros-grills manufactured by NORTH. Please, read carefully and keep it for future reference. This manual should be referred to both by installing or service technicians and the operators of the equipment.
  • Page 5: Technical Instructions

    TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY......................NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON-SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS.
  • Page 6 • Enter a suitable supply cord through the gland. • Depending on the available power supply connect the cables. a. Single phase power supply MKDKE6,MKDKE8, DKE6, DKE8 . Remove the provided bridges and short circuit L1, L2 and L3. Connect the phase to L1 or L2 or L3, the neutral to Ν1 or Ν2 and the earth...
  • Page 7 2.3 POSSIBLE PROBLEM…...………………………………………………………………………………… Even if the appliance is used correctly, some problems may arise for various reasons. The table that follows mentions some possible problems and some possible causes. In case of problem we control first if the electrical supply to the machine is right or not. POSSIBLE PROBLEM POSSIBLE CAUSES Machine is not operating...
  • Page 8 TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY....................... NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON-SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS.
  • Page 9 3.1 TURNING ON THE APPLIANCE ..................... After making sure the appliance has been correctly connected to electricity, you can start using it. Motor switch • Position 1 : Start spit’s rotation. • Position 0 : Stop spit’s rotation. Four position knobs (0,1,2,3) Depending on the desire heating position select the respective knob and adjust.

This manual is also suitable for:

Dke8Mkdke6Mkdke8

Table of Contents