Download Print this page

Adesso SOL FUSION PLUS Installation Manual page 5

Shower mixer

Advertisement

UPGRADING FROM UNEQUAL TO MAINS PRESSURE
1.
Remove the handle and disassemble the mixer:
3.
Unscrew the Venturi Jet using a 2.5mm Allen Key
5.
Reassemble mixer. Ensure that both black lines
marked on the cartridge and cartridge nut are
aligned when the mixer is in full cold position as
shown in Figure 1.
MAINTENANCE - CLEANING THE FILTER
1. Follow steps 1-2 above.
2. Flush out the disc in cold water.
3. Follow steps 4-5 above.
Patented New Zealand No. 605175
2.
Remove the insert disc using long nosed pliers by carefully
inserting the nose of the pliers into the indicated areas A & B.
4.
Refit the seal with silicone grease if required and then insert disc
using the long nose pliers, ensuring that the locating pins go into the
corresponding sockets.
REVERSE VIEW OF DISC
Locating pin
FRONT VIEW OF DISC
FILTER
Locating pin
Locating pin socket
REVERSE VIEW OF DISC
AREA A
AREA B
( FULL COLD POSITION )
Figure 1.
130422EI
Page 5

Advertisement

loading