Page 1
INSTALLATION GUIDE SOL FUSION PLUS® SHOWER MIXER SYSTEM REQUIREMENTS MINIMUM MAXIMUM Cold Unequal Pressure - Venturi jet installed 1500kPa (217.6psi) Operating Pressures - refer to the Venturi Selection Table on page 2 20kPa (2.9psi) 300kPa (43.5psi) Equal High (Mains) & Equal Low Pressures - Venturi jet removed 36kPa (5.1psi)
Page 2
IF YOU HAVE... EQUAL LOW PRESSURE OR EQUAL HIGH/MAINS PRESSURE Install product as supplied. UNEQUAL PRESSURE 1. Check your hot & cold water pressure 2. Follow this flowchart to select the correct Venturi Jet for the pressure situation: 76-130kPa 36-75kPa YELLOW 20-35kPa GREEN...
HOW TO INSTALL Cut a hole to suit faceplate No minimum straight distance Ø90mm Faceplate Min 40mm Max 70mm Apply a silicone bead on the back of the faceplate Page 3 Patented New Zealand No. 605175...
Page 4
TROUBLESHOOTING - SWAPPING OUT THE VENTURI JETS Remove the insert disc using long nose pliers by carefully Remove the handle and disassemble the mixer: inserting the nose of the pliers into the indicated areas A & B. AREA A AREA B Unscrew the Venturi Jet using a 2.5mm Allen Key Refit the correct Venturi Jet into the insert disc and hand tighten firmly...
Page 5
UPGRADING FROM UNEQUAL TO MAINS PRESSURE Remove the handle and disassemble the mixer: Remove the insert disc using long nosed pliers by carefully inserting the nose of the pliers into the indicated areas A & B. AREA A AREA B Refit the seal with silicone grease if required and then insert disc Unscrew the Venturi Jet using a 2.5mm Allen Key using the long nose pliers, ensuring that the locating pins go into the...