BONIS ST535 User Handbook Manual page 17

Temperature programmer
Hide thumbs Also See for ST535:
Table of Contents

Advertisement

Damper Output
To enter the damper temperature configuration menu press the ► key and
the t key down together while the controller is not running a program (firing
indicator not lit).
Note: in the sequence below if no key presses are detected within 30
seconds the ST535 will exit the menu and damper temperature changes
will not be saved.
DAMPER:C
150°C
DAMPER:O
300°C
The instrument will now reset and the new damper control temperatures will
be stored.
Note: in the sequence above it is important that the
total of 4 times else changes will not be saved.
Damper Operation
Prior to firing the damper will be open. During firing, when the kiln reaches
the damper close temperature, the damper will close. The event indicator
will be on.
At the end of the firing and when the kiln has cooled naturally to the damper
open temperature, the damper will open. The event indicator will be off.
ST535 User Handbook
The damper close temperature prompt is
shown. Release the u & t keys.
Press the u key.
The damper close temperature is now
shown. Adjust with the p & q keys (hold
down for acceleration).
Press the u key.
The damper open temperature prompt is
now shown.
Press the u key.
The damper open temperature is now
shown. Adjust with the p & q keys (hold
down for acceleration)
Press the u key.
u
key is pressed a
Page
17

Advertisement

Table of Contents
loading

Table of Contents