INV Abnormal
F18
(1) Please contact the distributor.
(1) Restart the inverter and wait until it functions normally.
Communication Fault
F32
(2) Contact customer service if error warning continues.
(1) Check if the local voltage and frequency is in
compliance with the machine speci cation;
W00
(2) If voltage and frequency are within the accepted
range, then wait 2 minutes for the inverter to function
W01
Grid Fault
normally; but if no recovery or fault repeats, please
W02
contact the local inverter customer service;
W03
(3) Contact the local power company if voltage and
frequency are beyond range or unstable.
(1) PV is not connected;
Solar Loss
W04
(2) Check grid connection;
(3) Check PV availability.
(1) Battery is not connected;
Bat Loss
W05
(2) Check if battery wiring port is short circuited;
(3) Contact customer service if error warning continues.
W06
(1) Check the battery availability;
Bat Volt Low
(2) Contact customer service if error warning continues.
W07
(1) Check if the battery is in line with the presetting;
(2) If so, power o and restart;
Bat Volt High
W08
(3) Contact customer service if error warning continues.
(1) Wait one minute for the inverter to restart;
Over Load Warning
W09
(2) Check whether the load is in compliance with the
speci cation;
(1) Check PV string for direct or indirect grounding
phenomenon;
(2) Check peripherals of machine for current leakage;
CFCI Over
W10
(3) Contact the local inverter customer service if fault
remains unremoved.
81
User Manual
Solutions
User Manual
(1) Check whether the installation follows the instructions;
LN Reverse
W11
(2) Contact customer service if error warning continues.
(1) Restart the inverter and wait until it functions normally.
Fan Fault
W12
(2) Contact customer service if error warning continues.
(1) Please contact the distributor.
BMS Fault
W14~ 25
W
10

Machine Parameters

Battery Speci cations
BluE-PACK5.1
Electrical
Energy Capacity
Battery type
Depth of Discharge (DoD)
Rated voltage
Operating Voltage Range
Operation
Maximum Charging Current
Maximum Discharging Current
Operating temperature range
0℃~+50℃(Charging)/-10℃ ~ +50℃(DisCharging)
Storage temperature range
Humidity
BMS
Modules Connection
Monitoring Parameters
cell temperature, PCBA temperature measurement
Communication
Ventilation type
Battery port
Grid port
Inrush current 22Aac, 3.2ms. fault current 25Aac,3.8ms,102Apeak.
Backup port
Inrush current 23Aac, 3.6ms. fault current 25Aac,3.4ms,99Apeak.
BluE-PACK10.2
5.12kWh
10.24kWh
LFP (LiFePO4)
90%
51.2V
44.8~56.5Vdc
50A (0.5C)
100A (0.5C)
80A (0.8C)
100A (0.5C)
-20℃ ~ +50℃
0% ~ 90%
Max. 4 batteries in parallel
System voltage, current, cell voltage,
CAN and RS-485 compatible
Passive and active cooling
Rated current
82