  • Page 1 DIGITEL QPC Controller Instruction manual www.gammavacuum.com 900031_J Original instructions...
  • Page 2 Copyright notice © Gamma Vacuum 2021. Part of the Atlas Copco Group Trademark credit Gamma Vacuum and the Gamma Vacuum logo are trademarks of 2700 4th Avenue East, Ste 100, Shakopee, MN 55379, USA Disclaimer The content of this manual may change from time to time without notice.
  • Page 3: Table Of Contents

    5.6. DIGITEL QPC Setup........
  • Page 4 9.7. Digital input setup..........23 9.8.
  • Page 5 15.3.2. Required documentation........54 Disposal............55 900031_J Page 5...
  • Page 6 List of Figures Figure 1: QPC front panel........... 17 Figure 2: Home screen.
  • Page 7: Safety And Compliance

    900031_J - Safety and compliance Safety and compliance 1.1. Definition of Warnings and Cautions NOTICE: For safe operation from the start, read these instructions carefully before you install or commission the equipment and keep them safe for future use. Read all the safety instructions in this section and the rest of this manual carefully and make sure that you obey these instructions.
  • Page 8: Safety Symbols

    900031_J - Safety and compliance 1.2. Safety symbols The safety symbols on the products show the areas where care and attention is necessary. The safety symbols that follow are used on the product or in the product documentation. Warning/Caution An appropriate safety instruction must be followed or caution to a potential hazard exists.
  • Page 9: Safety Notices

    Verletzungen equipo. oder Schäden an der Anlage führen. 1.4. Safety notices 1. Gamma vacuum controllers designed for ion pump operation are capable of delivering 7 kV under open-circuit or low-pressure operating 900031_J Page 9...
  • Page 10 900031_J - Safety and compliance conditions. Gamma vacuum products are designed and manufactured to provide protection against electrical and mechanical hazards for the operator and the area surrounding the product. 2. Installation procedures are for use by qualified, authorized personnel who have experience working with 50 V or greater.
  • Page 11: General Information

    900031_J - General information General information The DIGITEL QPC is an ion pump and TSP power supply controller. It is designed to operate up to four ion pumps and up to two Titanium Sublimation Pumps (TSP). It can accommodate any ion pump size up to 1200 L/s.
  • Page 12: Unpacking The Controller

    Vacuum for authorization and return instructions. 3.2. Check the equipment received Make sure that all items shipped have been received. If any items are missing, notify the carrier and Gamma Vacuum. Save all packaging material for inspection. 900031_J Page 12...
  • Page 13: Installation

    900031_J - Installation Installation The DIGITEL QPC is a 1/2 rack controller. It can be joined with a second QPC, or it can be installed with a 19 in. rack mount kit (pn 310116). When installing rack mount kit, use M4 x 8 mm screws, quantity 11. (Longer screws will damage electronics inside the unit).
  • Page 14: Controller Configuration

    Controller configuration Following configuration options are specified at the time of order: 5.1. Number of HV channels DIGITEL QPC can have up to four independent HV channels. 5.2. Output voltage polarity type for each HV channel Following options are available: ▪...
  • Page 15: Digitel Qpc Setup

    900031_J - Controller configuration 5.6. DIGITEL QPC Setup 900031_J Page 15...
  • Page 16: Pressure Measurement

    900031_J - Pressure measurement Pressure measurement Pressure value is determined using following equation Where: I - Current in amps. V - Voltage in volts. U - Pressure units conversion factor (1 for Torr, 1.33 for mbar and 133 for Pascal). F - Configured pump pressure factor.
  • Page 17: Front Panel

    900031_J - Front panel Front panel Figure 1. QPC front panel 7.1. Description Front panel contains: ▪ Main power on and off rocker type switch. Soft type switch. Input power still partially present when in off position. ▪ Main power indicator lamp. Color green. When illuminated indicates input power present.
  • Page 18: Hv Control Or Ion Pump Operation

    900031_J - HV control or ion pump operation HV control or ion pump operation 8.1. Prior to using an ion pump Confirm following: ▪ Rough pump down to 1 x 10 torr or less (the lower the better). 1 x 10 torr is recommended.
  • Page 19: Touchscreen User Interface

    900031_J - Touchscreen user interface Touchscreen user interface 9.1. Home screen Touch anywhere on the screen to invoke button controls. Available setup: View TSP - Switches home screen to TSP view. Button is available only if remote TSP controller is connected to the QPC controller.
  • Page 20: Supply Setup Advanced Options

    900031_J - Touchscreen user interface Pump size (L/s) - Configures pump size (0 - 1200). Auto restart - Configures supply auto HV restart at controller power up (on and off). Output voltage (V) - Configures output voltage target level (3 - 7 kV). Current limit (mA) - Configures output current limit (2 - 125 mA).
  • Page 21: System Setup

    900031_J - Touchscreen user interface 9.4. System setup Available setup: Language - Configures user interface language. Pressure units - Configures system pressure units (Torr, mbar, Pascal). Fan control - Configures fan control (on, auto). Restore default settings - Resets settings to system defaults. Figure 6.
  • Page 22: Analog Output

    900031_J - Touchscreen user interface 9.6. Analog output Total of four analog outputs on connector J104: Analog output 1 (J104, pin 30) Analog output 2 (J104, pin 32) Analog output 3 (J104, pin 34) Analog output 4 (J104, pin 36) By default, all analog outputs are turned off (function set to off).
  • Page 23: Digital Input Setup

    900031_J - Touchscreen user interface Step 2: If ‘Output state = Inverted’ multiply current log value in step 1 by (-1) Step 3: Add offset value (-9 + 11 = 2 V) The analog output pin will read 2 V. Figure 8.
  • Page 24: Digital Output Setup

    900031_J - Touchscreen user interface TSP 2 interlock function Ground pin to satisfy TSP 2 interlock. if interlock is not satisfied, TSP 2 cannot run. Supply source - Selects supply that will be controlled by this setup. Figure 9. Digital input setup screen 9.8.
  • Page 25: Relay Setup

    900031_J - Touchscreen user interface HV output state function: Digital output is asserted when supply is on (HV on), or de-asserted when supply is off (HV off). Supply source - Selects supply driving digital output. Figure 10. Digital output screen 9.9.
  • Page 26: Serial Port Setup

    Serial protocol - Selects serial protocol running on the serial port. Supported protocols are Gamma, Modbus ASCII, and Modbus RTU. NOTE: Modbus register map is available on Gamma Vacuum website under download section. Figure 12. Serial port setup screen 9.11.
  • Page 27: Ethernet Interface Setup

    Gateway address - Configures Ethernet gateway address. Link state - Information only. Supported protocols: Gamma protocol (running on TCP port 23) Modbus TCP protocol (running on TCP port 502) NOTE: Modbus register map is available on Gamma Vacuum website under download section. 900031_J Page 27...
  • Page 28: Tsp Sublimation View

    900031_J - Touchscreen user interface Figure 14. Ethernet setup screen 9.13. TSP sublimation view First text line indicates current TSP status. Here ‘TSP 1 OFF’. Second text line indicates current TSP configuration as defined in the TSP Setup window. Third text line indicates currently active TSP filament. This is the filament that will be sublimated.
  • Page 29: Tsp Sublimation View With Controls

    900031_J - Touchscreen user interface Figure 15. TSP sublimation view screen (no control buttons) 9.14. TSP sublimation view with controls View pump - Switches home screen to pump view. Menu - Invokes main menu. Exit - Clears screen and hides control buttons. Turn On TSP (Turn Off TSP) - Starts TSP programmed mode according to the parameters defined in TSP setup window.
  • Page 30: Tsp Pressure Window Setup

    900031_J - Touchscreen user interface Current target (A) - Sublimation current target level. On time (s) - Cycle sublimation time in seconds. Number of cycles - Number of sublimation cycles to run. Cycle period - Time in minutes between each sublimation cycle. Not applicable when number of cycles is 1.
  • Page 31: Tsp Advanced Options

    900031_J - Touchscreen user interface Figure 18. TSP pressure window screen 9.17. TSP advanced options Available setup: Pressure window - Invokes pressure window setup. Control - Sets TSP control in either Amps or Watts. Filament status clear - Clears filament status for all filaments. Filament auto advance - Sets filament auto advance option (off, next, rotate).
  • Page 32: Error/Status Codes

    900031_J - Error/status codes Error/status codes Figure 20. Display error/status codes screen 10.1. Error example ‘STANDBY, Error 02, vacuum loss, detected’ ‘STANDBY’ - Indicates supply HV can be turned on. In comparison, ‘DISABLED’ indicates supply HV cannot be turned on. Turning on supply HV will clear all outstanding errors not requiring user intervention.
  • Page 33 Supply not calibrated. Current metering might not be accurate. Supply over-temperature detected. HV cannot run. Note: If error code is not listed in the table please contact Gamma Vacuum for more information. Technician type errors are not listed in the users manual. 900031_J...
  • Page 34: Rear Panel

    Connector J113, CTRL Standard Sub-D 15-pin female connector. Used in combination with Remote TSP and NEG Controller to facilitate communications between controllers. Connection is made using straight- through Sub-D 15-pin cable available from Gamma Vacuum (PN 380049 - 900031_J Page 34...
  • Page 35: Connector J114, Eth

    900031_J - Rear panel length 3 m, PN 380050 - length 6 m, PN 380085 - length 15 m, PN 380895 - length 30 m). 11.4. Connector J114, ETH Standard RJ-45 connector. Connection to Ethernet interface. Connector has two LED indicators ▪...
  • Page 36: Connector J112, Ser

    900031_J - Rear panel Description DIGITAL IN 3 - input, pulled-up internally to + 3.3V, ground to activate assigned function DIGITAL IN 4 - input, pulled-up internally to + 3.3 V, ground to activate assigned function + 12 V d.c. - supply, regulated, 80 mA maximum Not connected Not connected Reserved - do not use, ground...
  • Page 37 900031_J - Rear panel RS-485 full duplex (4 wire) RS-485 half duplex (2 wire) +TX/+RX -TX/-RX 900031_J Page 37...
  • Page 38: Serial Communication

    Following serial protocols are supported: ▪ Gamma protocol ▪ Modbus ASCII protocol ▪ Modbus RTU protocol Note: Modbus register map is available on Gamma Vacuum website under download section. 12.1. Gamma protocol over serial connection Gamma protocol command packet structure over serial connection The command packet is made up of at least five fields.
  • Page 39: Gamma Protocol Response Packet Structure Over Serial Connection

    900031_J - Serial communication Field Size Comment CHECKSUM 2 ASCII hex characters Computed checksum of packet The calculated checksum must have its value in ASCII hexadecimal notation. It is calculated by adding the decimal value of all characters in the packet (excluding start, checksum, and terminator), and then dividing the result by 256.
  • Page 40 900031_J - Serial communication Field Size Comment For an error condition with an incoming command, this field returns an error number to the controlling computer. For non-error conditions, this field returns a status byte/word to the controlling computer. See Table: Response code error codes.
  • Page 41: Crc Checksum Example

    0x122 mod 0x100 and result is 0x22. This is the command checksum. 3. The command to be sent to the unit is, ‘~ 01 01 22’ + cr. 4. The unit will respond with, ’01 OK 00 DIGITEL QPC E1’. 5. To verify checksum for the response, perform similar calculations.
  • Page 42: Examples - Gamma Protocol Over Serial Connection

    900031_J - Serial communication Characters Value (Decimal) Value (Hex) space 0x20 0x30 0x30 space 0x20 0x44 0x49 0x47 0x49 0x54 0x45 0x4C space 0x20 0x51 0x50 0x43 space 0x20 Total = 1249 Total = 0x4E1 12.4. Examples - Gamma protocol over serial connection Following strings represent valid commands and corresponding checksums.
  • Page 43: Gamma Protocol Commands

    900031_J - Serial communication Rx – “01 OK 00 1.0E-11 TORR A5” + cr 12.5. Gamma protocol commands List of supported Gamma protocol commands. Note, S parameter indicates supply (1 - 4), and T parameter indicates TSP (1 - 2). Table 9.
  • Page 44 900031_J - Serial communication Command Description Parameter Response Data/response interpretation code 0x28 Turn off TSP where T is TSP 0x29 Set TSP active T, X where T is TSP and X is filament filament number (1-4) 0x2B Clear TSP where T is TSP filament status Clears status for all TSP filaments 0x2D...
  • Page 45 900031_J - Serial communication Command Description Parameter Response Data/response interpretation code 0x43 Get/set supply S, X where S is supply and X is the new current limit current limit in mA (2-125). If only S parameter is specified, the configured current limit is returned in the form ‘X’...
  • Page 46 900031_J - Serial communication Command Description Parameter Response Data/response interpretation code 0x5A Get/set analog N, S, F, O, S, F, O, Where: output I, R I, R N is analog channel (1-4) S is supply (1-4) O is log offset (-15 to +15) I is inverted mode (0 for normal, 1 for inverted) R is response mode (0 for normal,...
  • Page 47 900031_J - Serial communication Command Description Parameter Response Data/response interpretation code 0x79 Set TSP T, M, N, T is TSP configuration X.XE-XX, M is cycle period in minutes (time Y.YE-YY, between fires) D, P N is number of cycles to run X.XE-XX is high pressure limit Y.YE-YY is low pressure limit D is on time in seconds...
  • Page 48 900031_J - Serial communication Command Description Parameter Response Data/response interpretation code 0xE0 Get TSP filament T,X,X,X,X where T is TSP and X is filament status status (0 for good, 1 for open/ questionable) 0xE0 Get TSP filament T,X,X,X,X where T is TSP and X is filament status status (0 for good, 1 for open/ questionable)
  • Page 49: Ethernet Communication

    Following protocol are support over Ethernet connection: Gamma Protocol (Running on TCP port 23) Modbus TCP Protocol (Running on TCP port 502) Note: Modbus register map is available on Gamma Vacuum website under download section. 13.1. Gamma protocol over ethernet connection...
  • Page 50: Example - Gamma Protocol Over Ethernet Connection

    13.2. Example - Gamma protocol over ethernet connection Command code 0x01 - get controller model Tx – “cmd 01” + cr. Rx – “OK 00 DIGITEL QPC” + cr + cr + lf + “>” characters 900031_J Page 50...
  • Page 51: Technical Specifications

    900031_J - Technical specifications Technical specifications Dimensions (maximum) 450 X 208 X 130 mm, length x width x height (3U high, 1/2 rack wide) Shipping weight (maximum) 11 (25) kg (lbs) (fully configured with four supplies) Operating temperature 0 to 40 °C free airflow around the unit is required. Altitude Sea level to (2000 m) 6560 ft.
  • Page 52: Warranty And Service

    LCD screen and finish of the unit. 15.1.2. Service requests Upon notification, Gamma Vacuum will identify the level of service required. To assist in this process, please provide the following information in as much detail as possible: ▪...
  • Page 53: Warranty

    Gamma Vacuum, free from defects in material and workmanship. As Buyer’s sole exclusive remedy under this warranty, Gamma Vacuum agrees to either repair or replace, at Gamma Vacuum’s option and free of parts charge to Buyer, and part or parts which, under proper and normal conditions of use, prove to be defective within twelve (12) months from the date of receipt by buyer.
  • Page 54: Returning Material

    Return, repairs, or credit will not be authorized until this form has been signed and returned. NOTE: Prior to returning any materials, Gamma Vacuum must issue an RMA. The RMA number should be clearly labelled on all shipping information and packages. 900031_J...
  • Page 55 900031_J - Disposal Disposal Dispose of the pump and any components and accessories safely and in accordance with all local and national safety and environmental requirements. Particular care must be taken with any components that have been contaminated with dangerous process substances. Take appropriate action to avoid inhalation of any particles that may be present in the pump.
  • Page 56 EU Declaration of Conformity Gamma Vacuum Documentation Officer Part of the Atlas Copco Group Jana Sigmunda 300 2700 4 Ave E, Suite 100 Lutín , 78349 Shakopee, MN 55379 Czech Republic T: +42(0) 580 582 728 documentation@vt.atlascopco.com The product specified and listed below...
  • Page 57 2021-04-21 You must retain the signed legal declaration for future reference This declaration becomes invalid if modifications are made to the product without prior agreement. Signed for and on behalf of Gamma Vacuum Ian Keech, VP Engineering Marcus Thierley...
  • Page 58 ADDITIONAL LEGISLATION AND COMPLIANCE INFORMATION EMC (EU, UK): Class A/B Industrial equipment Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. RoHS (EU, UK): Material Exemption Information This product is compliant with no Exemptions REACH (EU, UK) This product is a complex article which is not designed for intentional substance release.
  • Page 59 2700 4th Avenue E, Suite 100, Shakopee, MN 55379, USA. 1 800 237 3603, 952 445 4841 1 952 445 7615 info@gammavacuum.com www.gammavacuum.com © Gamma Vacuum 2020. | Part of the Atlas Copco Group...

Table of Contents