1. SAFETY
1.1.
PERSONAL PRECAUTIONS
Wear safety eye protection and protective clothing. Avoid touching eyes while working near battery.
9
Wash immediately with soap and water if battery acid contacts skin or clothing. If acid enters eye, flush eye immediately with cool,
9
clean running water for at least 15 minutes and seek immediate medical attention.
Remove personal metallic items such as rings, bracelets, necklaces and watches.
9
A lead-acid battery can produce a short-circuit current which is high enough to weld such items to the vehicle and cause severe burns.
DO NOT smoke or allow a spark or flame in the vicinity of the battery or engine.
8
WARNING! To prevent the risk of sparking, short circuit and possible explosion. DO NOT drop metal tools in the battery area, or allow
them to touch the battery terminals.
DO NOT cross-connect unit to battery. Ensure positive (RED) clamp is to positive terminal and negative (BLACK) clamp is to negative
8
terminal.
1.2.
GENERAL SAFETY
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using this unit.
Use in conjunction with manufactures workshop manuals/information.
9
Maintain this product in good working order and condition, take immediate action to repair or replace damaged parts.
9
Use approved parts only. Unapproved parts may be dangerous and will invalidate the warranty.
9
DO NOT use to perform a task for which it is not designed.
8
DO NOT allow untrained persons to use the unit.
8
DO NOT use when tired or under the influence of drugs, alcohol or intoxicating medication.
8
AVOID direct inhalation of smoke.
8
WARNING! DO NOT pollute the environment by allowing uncontrolled discharge of fluids.
Keep children and unauthorised persons away from the work area.
9
Keep work area clean and tidy and free from unrelated materials.
9
Ensure the work area has adequate lighting.
9
Wear suitable clothing to avoid snagging. DO NOT wear jewellery, and tie back long hair. A full range of personal safety equipment is
9
available from your Sealey stockist.
WARNING! Unit may get HOT!
Power Supply: 12V dc.
9
Maximum input pressure: 15psi (1bar).
9
Use mineral oil (baby oil) ONLY.
9
DO NOT remove filler cap when unit is ON.
8
Keep unit upright at all times to avoid oil leaking out.
9
When not in use, clean unit and store in a safe, dry,
9
childproof location.
Ensure that mineral oil (baby oil) safety data sheet
9
has been read, and that user understands the health
risks involved and uses appropriate personal protective
equipment.
2. INTRODUCTION
Allows the technician to pinpoint all manner of system leaks
including the air intake, cooling, evaporation, fuel, exhaust and
vacuum systems. Fast and simple-to-use, maximising earning
potential. System is clean and quick to use and connects to a 12V
vehicle battery. Features air and smoke mode with pressure gauge
display. Supplied with cone adapter, power cord clamp, valve core
wrench, test oil refill bottle, smoke hose, EVAP connector, universal
airbag adapter, 8 x rubber blanking cones. Mineral oil not included.
© Jack Sealey Limited
SMOKE DIAGNOSTIC TOOL - LEAK DETECTOR
VS868
MODEL No:
Wear a mask
Keep away
from rain
Original Language Version
Smoke Mode
Button
Air Mode
Button
Pressure
Gauge
Overheat
Alarm Light
Oil Filler Cap
Power
fig.1
Light
VS868 Issue 1 13/12/21

Advertisement

loading

Summary of Contents for Sealey VS868

  • Page 1 VS868 MODEL No: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Smoke and oil will oxidise and deteriorate after being in high temperature for a long time, which will affect the service life of the smoke generator. Please change the test oil regularly. fig.3 VS868 Issue 1 13/12/21 Original Language Version © Jack Sealey Limited...
  • Page 3 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...