P u l s a t o r S y s t e m
When the pulsator is rotated C.W or C.C.W at a high speed, it makes the cyclone water flow from the asymmetrically
designed pulsator as shown below.
A u t o ma t ic D r a in n in g t ime A d j u s t me n t
This system adjusts the draining time automatically according to the draining condition.
Draining
condition
FUNCTIONAL PRINCIPLE
The micom can remember the time from the begining of drain to reset point when the pressure switch reaches to
1
"OFF" point
Drain Time
Less than
10 minutes
More than
10 minutes
In case of continuous draining, residual drain time is determined by micom.
2
Draining time as a whole = D + 30
12
EXPLAN ATION 
Good draining
The washer begins spin process after drainage.
Bad draining
Draininig time is prolonged.
No draining
Program is stopped and gives the alarm.
Movement of the Program
Continue draining
Program stops and gives the alarm with
Residual drain time.
The time remembered by micom.
Asymmetrically designed pulsator
makes the cyclone water flow, which get
rid of the washing dead zone to
increase the washing effect and reduce
the entanglement of laundry.