Download Print this page

Daewoo DWF-5510 Service Manual page 14

Hide thumbs Also See for DWF-5510:

Advertisement

PRINCIPLE OF INTAKE & OUTLET OF THE AIR
INTAKE : ARMATURE moves up, and BELLOWS inhales the air. At the same time, protector B is open and A is
close.
OUTLET : ARMATURE moves down, and BELLOWS exhausts the air. At the same time, protector B is close and A
is opend.
FUNCTIONAL PRINCIPLE OF TRANS & MAGNET
The phase of A.C electric power changes to 60 cycle/second.
¡
The magnetic pole of trans core is changed by the change of the phase of A.C electric power.
¡
The core repeats push and pull (3600 times/min.) of the at mature magnet.
¡
A.C
N
S
F u n c t io n a l P r in c ip l e o f B u b b l e Wa s h in g M ac h in e
ACROSS SECTION
FUNCTIONAL PRINCIPLE
Bubble generator supplies the air from the bottom of outer tub to the inner space of pulsator, the air is dispersed by
the rotation of pulsator. Air-bubble is created by the centrifugal force, and rises up.
A.C
LEAF SPRING
TRANS CORE
NS
MAGNET
S
NS
N
Air bubble
Tub
Outer tub
Pulsator
Nozzle
EXPLAN ATION 