Operation Manual / Power2 850-M / High-pressure stage
8 Troubleshooting / 8.4 Malfunctions when stopping
8.4
Malfunctions when stopping
Runout noises
Possible causes
Low-pressure
Pressure stage contaminated
or
Bearing damaged
high-pressure
Rotor rubbing
stage
Foreign object in the pressure stage
Table 37: Malfunctions when stopping – Runout noises
Runout time too short
Possible causes
Low-pressure
Pressure stage contaminated
or
Bearing damaged
high-pressure
Rotor rubbing
stage
Foreign object in the pressure stage
Table 38: Malfunctions when stopping – Runout time too short
8.5
Speed measurement system
Measured speed incorrect
Possible causes
Low-pres-
- -
sure or
high-pres-
sure stage
Table 39: Measured speed incorrect
© Copyright 2022 ABB. All rights reserved.
Remedy
Clean
Contact a Turbo Systems service sta-
tion
Remedy
Clean
Contact a Turbo Systems service sta-
tion
Remedy
Contact a Turbo Systems service station
HZTL4063_EN
Rev.F
March 2022